NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Final TEM air analysis report, 2005

Machine-extracted title · confidence 18%

Final TEM air analysis laboratory report for 4 Liberty Plaza, Mar 2005.

NYC-WTC_000422612–000422613
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

RJ LeeGroup, Inc. 350 Hochberg Road, Monroeville, PA 15146 Phone: (724) 325-1776 Fax: (724) 733-1799

Final Laboratory Report TEM Air Analysis RJ Lee Group, Inc. Report Date: 3/20/2005 350 Hochberg Road Sample Receipt Date: 3/19/2005 Monroeville, PA 15146 RJ Lee Group Job No.: TCN409139-33 USA Samples Received: 4 Method: Federal Register, 40 CFR, Part 763, October 30, 1987 Building: 4 Albany

Concentration

Date-Time Collected Filter Area Asbestos Analytical RJLG Sample Sample Start Area Volume Analyzed Structures Sensitivity Number Type Stop ■Sub Location I Comments- (mn?) (liter) (mirf) Chry Amph (S/mirf) (S/cc) 52483 lO.HT Area 3/18/2005 - 15:03:00 (North) - 385 1372.50 0.18286 3 0 16.4 0.005 3/18/2005 - 18:06:00 ono2

5248311.HT Area 3/18/2005 - 15:03:00 (West) - 385 1496.00 0.18286 1 0 0.001 3/18/2005 - 18:10:00 03)01

5248312.HT Area 3/18/2005 - 15:03:00 (Central) - 385 1480.00 0.18286 0 10.9 0.003 3/18/2005 - 18:08:00 0.00 f

5249842.HT Area AL?/29 Q5-15i03:00 (East) - 385 1770.00 0.18286 3 0 16.4 0.004 3/18/2005 - 18:00:00 "5.5 Wi

Authorized Signature: Kimberly A. Allison, Manager - TEM Analysis

Notes; 1. Volumes provided by Deutsche Bank were used to calculate analytical results and sensitivities. 2. “<” indicates results less than analytical sensitivity. “—” indicates that sample was not analyzed. 3. Sample(s) for this project were analyzed at our: Monroeville, PA (NVLAP #101208-0, NY ELAP #10844) facility. 4. If RJ Lee Group, Inc. did not collect the samples analyzed, the verifiability of the laboratory's results are limited to the reported values. 5. Abbreviations; N/A-Not Applicable, Chry-Chrysotile Asbestos, Amph-Amphibole Asbestos, S-Stnictures. 6. Samples will be held for 90 days and then disposed of per Federal regulations. 7. These results are submitted pursuant to RJ Lee Group’s current terms and conditions of sale, including the company’s standard warranty and limitation of liability provisions. No responsibility or liabihty is assumed for the manner in which these results are used or interpreted.

Page 1 of 2

CITY_DEP_WORBY_CANNATA_SUBP_000055435

NYC-WTC_000422612

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000422612Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000426955

Final TEM air analysis report dated 3/19/2005 for building 4.

Similar indexed content

NYC-WTC_000426493

Final TEM air analysis lab report dated 3/19/2005.

Similar indexed content

NYC-WTC_000424474

Final TEM air analysis report dated 3/20/2005 for building 4.

Similar indexed content

NYC-WTC_000427150

Final TEM air analysis report for building 4, dated March 19, 2005.

Similar indexed content

NYC-WTC_000423639

Final TEM air analysis laboratory report for building 4, date 7/21/2005.

Similar indexed content

Compare copies and versions →