NYC 9/11 Public Portal Document
NYC Response
Asbestos Air Sampling Results at Fixed Locations Data Validation Date; 03/03/2002
Sampiing Date and Time: 3/1/20020001 to 1200
PCM by NiOSH 7400 ___________ TEM { AHERA) PCM fibers
Sampling Sampling Sample Structures (#)
Dats Sample No. Location Vo! urns* Matrix f/mm=^ f/cc G,5p - Sp 5|t S/mm" S-f/cc*’'
03/01/02 TTW-01018 W 1149.75 Air <7.0 <0.002 0 0 <13.33 <0.0045
03/01/02 FB030102 Field Blank 0 Air <7.0 n/a NA<=^> NA<” NA<=> NA<=>
03/01/02 TB030102 Trip Blank 0 Air <7.0 n/a NA«> NA»> NA<=^> NA<2>
03/01/02 TTW-01019 E 1144.1 Air <7.0 <0.002 0 0 <13.33 <0.0045
03/01/02 TTW-01020 S 1045.5 Air <7.0 <0.003 0 0 <11.43 <0.0042
03/01/02 TTW-01021 V 1144.1 Air <7.0 <0.002 0 0 <13.33 <0.0045
03/01/02 TTW-01022 u 1130.5 Air <7.0 <0.002 0 0 <13.33 <0.0045
03/01/02 TTW-01023 K 1116.9 Air <7.0 <0.002 0 0 <13.33 <0.0046
03/01/02 TTW-01024 D 1085 Air <7.0 <0.002 0 0 <13.33 <0.0047
03/01/02 TTW-01025 C 1082.4 Air <7.0 <0.002 0 0 <13.33 <0.0047
03/01/02 TTW-01026 B 977.5 Air <7.0 <0.003 0 0 <11.43 <0.0045
03/01/02 TTW-01027 A-Dup 1113.5 Air <7.0 <0.002 0 0 <13.33 <0.0046
03/01/02 TTW-01028 A 1006.25 Air <7.0 <0.003 0 0 <11.43 <0.0044
03/01/02 TTW-01029 F 1137.3 Air <7.0 <0.002 0 0 <13.33 <0.0045
03/01/02 TTW-01030 Q 1141.9 Air <7.0 <0.002 0 0 <13.33 <0.0045
03/01/02 TTW-01031 J-Dup 1037 Air <7.0 <0.003 0 0 <11.43 <0.0042
03/01/02 TTW-01032 J 1260 Air <7.0 <0.002 0 0 <16.00 <0.0049
03/01/02 TTW-01033 N 957.25 Air <7.0 <0.003 0 0 <11.43 <0.0046
03/01/02 TTW-01034 Ml 980 Air <7.0 <0.003 0 0 <11.43 <0.0045
03/01/02 TTW-01035 L 1097.25 Air <7.0 <0.002 0 0 <13.33 <0.0047
03/01/02 Air 30.57 0 0 <11.25 <0.0043 24
03/01/02 Air <7.0 <0.002 NA<^> NA<"> NA<=> NA<">
03/01/02 Air <7.0 <0.002 NA<=^> NA<” NA<=> NA<=>
Please Note the Sampling route has been reversed
o Sampling Locations: Key;
A: NE corner of West Broadway & Barclay M: Western end of Harrison St. at West St. * Sample volumes (liters) are below
1^
B: SE corner of Church & Dey St. (on tree next to bulkhead) recommended limit for the TEM method; volume is
o C: Trinity (a.k.a. Church) & Liberty Ml : West St. - 50 yards south of Harrison St. at bulkhead based on pump reading
m
Cl: SW corner of Broadway & Liberty St. N: South side of Pier 25 (next to volleyball ct) ** Structure (S) is roughly equivalent to fiber (f)
D: East end of Albany St. at Greenwich St. P: NE corner of South End Ave. & Albany *** Chrysotile
E: Western end of Liberty St. at South End Ave Q: Barclay & West St. (center island) in **** Extremely low sample volume collected
o F: Northern median strip of Vesey & West St proximity to USCG command post ***** Amosite
J]
□0 G: Church and Duane St. R: TAGA Bus Location NA’’’ - Not analyzed due to overloading of
H: South side of Chase Manhattan Plaza at Pine St. S: Rector & South End particulates
'o
>
I: SE corner of Wall St. & Broadway
J: NE corner of Warren & West St.
T: Pier 6 Heliport
U: Pier 6 Exit 2
NA® - Not analyzed for TEM
n/a - Not applicable
z K: West St. & Albany in median strip V: Pier 6 Bus Sign NR - Not requested
z L: On walkway toward North Park rec area (north side W: Wash Tent Common Area NS - Sample not submitted
>
s
of Suyvesant High), access to TAGA bus area
NiOSH 7400; Fiber Analysis of Air Samples via NiOSH 7400, Revision 3, issue 2, 8/15/94
c Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA 40CFR Part 763 (AHERA)
□0
1"° Ln
o
o
o
o
CD
on
CD
NYC-WTC_000421563
OCR can misread numbers and units. Confirm readings against the page image before using them.