NYC-WTC_000104027
Summary of ambient air sampling and visual observations at 105 Duane Street following the WTC collapse.
17 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗AMBIENT AIR SAMPLING REPORT for Rector Street site; sampling dates in Sept/Oct 2001.
NYC-WTC_000419770–000420230OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC ASSOCIATES INC. - TEM ANALYSIS LAO GROUP 4: 5579 - 09/29/01
Lab Sample No. 59764 Filter Type NICE 25 mm Operator_________________
Client Spl. No. T41 Filter Area 395 mni-2
Instrument I.U. EM 10 CR% Grid I.D. Oink No.
Screen Magnification 16 400X (GO) Area 0.01124 mm^2 Corrments
Ace. Voltace 80 kV No. GO to be Analyzed 6 ( 4.721 Struct. Gerund. to 70 s/mm^2.)
I.D. of Structure EDS Structure Structure Type Length N or/ GO. (Nonasb. hN.Co.rd. No. F B C M >o.s um 5um Nonasb. Ambig./ND Elements) , 5um Chrys. Amphibole
___ riio,.0 nu, tlrUln i IL! U aaueeeus— containing samples) ...~,....J IGrid acceotanceI -. II:_ structures up to 704 itim (let 4) <50% undissolve OiLer, overlapped or folded Struct. _ > 0.5um --> 5:1 Aspect Ratio <10% particulate coverage >50% coverage Totals N= Not Observed (EDS spectrum or diffraction pattern) lot least 20 unfolded or overlapped grid squares Positive diffraction pattern properties conforming <5% holes or opaque areas F B C M > 5um to laboratory Identification criteria observed. Unu.od portion For chry.oUle: o.T3nm spacin` far (020) reflection., of filter Chrysotile 0.53nm spacing for the Isyer line repeat, streaking Avoided portion of (110) and (130) reflection.. of filter Par amphibole.: 0.53nm layer line repeat, and ■pprox. fester (2mm side) 3A ratio of non—ginned layer line spot spacing to Poft on of Amphibole amin.Uon layer line repeat distance (0.53nm). ✓= EDS spectrum conforming to laboratory AMPHIBOLES Ambiguous identification criteria observed. F= Single Fiber (1-3 intersections = 1-3 fibers) Amosite
h -H R= Bundle (>3 fibers <1 fiber diameter apart) 25mm filter Crocidolite Non —asbestos C= Cluster (>3 inter.ectiona) Slapping Ruler Anthophyilite K= itatri. >50 ./0.O. or in lot 4 C.O. Tremolite NSD= No Structures Detected Actinolite Non -Identified L•\DATA\PRIVATE\MIKEC\CADD\TE1t3 0/22/90
CITY 21MC100 004915900
NYC-WTC 000419846
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000104027
Summary of ambient air sampling and visual observations at 105 Duane Street following the WTC collapse.
17 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329958
Summary and conclusion of TEM results for Man Tech project.
11 shared non-person entities · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000104321
Second volume of ambient air sampling and visual observation results for 105 Duane Street after the WTC collapse.
14 shared non-person entities · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000106077
Chain of custody documentation for background sampling including asbestos and lead at 250 Broadway in September 2001.
11 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237389
Laboratory report documenting transmission electron microscopy results for asbestos fiber analysis at 40 Rector Street floors 16-18.
7 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237252
Laboratory report documenting transmission electron microscopy analysis of air samples from floors 12 and 14 at 40 Rector Street.
7 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237472
Laboratory report documenting asbestos fiber analysis by TEM for an air sample from 40 Rector Street collected on October 23, 2001.
7 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237385
Laboratory report documenting transmission electron microscopy results for asbestos fiber analysis at 40 Rector Street floors 16-18.
7 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000105975
Summary of transmission electron microscopy results for asbestos samples from 250 Broadway dated September 16, 2001.
6 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000174866
Laboratory data sheet documenting asbestos fiber counts from air samples collected on floors 15 through 17.
5 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237327
Laboratory report page containing specific air volume and sample identification data for transmission electron microscopy asbestos fiber analysis at 40 Rector Street.
7 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000174896
Laboratory report detailing asbestos fiber analysis by TEM for samples from floors 16-18 at 40 Rector Street collected October 19, 2001.
5 shared non-person entities · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000237261
Technical data sheet recording transmission electron microscopy measurements for air sample analysis at 40 Rector Street dated September 23, 2001.
Similarity score 0.985 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000271031
TEM lab report for asbestos analysis of sample 62724, 5793 group, 10/30/01.
Similarity score 0.985 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237495
Laboratory report documenting transmission electron microscopy analysis of a bulk sample collected on October 23, 2001.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000174894
Laboratory report containing transmission electron microscopy data and images for asbestos fiber identification from samples analyzed in September 2001.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270151
TEM analysis data for a sample from the Education Dept., includes instrument and structural details.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270444
TEM analysis parameters for NSHS-EIR-10/14-04; structure ID and EDS data, 385 mm2.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000104027
Summary of ambient air sampling and visual observations at 105 Duane Street following the WTC collapse.
Similar indexed content
Summary and conclusion of TEM results for Man Tech project.
Similar indexed content
Second volume of ambient air sampling and visual observation results for 105 Duane Street after the WTC collapse.
Similar indexed content
NYC-WTC_000106077
Chain of custody documentation for background sampling including asbestos and lead at 250 Broadway in September 2001.
Similar indexed content
NYC-WTC_000237389
Laboratory report documenting transmission electron microscopy results for asbestos fiber analysis at 40 Rector Street floors 16-18.
Similar indexed content