NYC-WTC_000104027
Summary of ambient air sampling and visual observations at 105 Duane Street following the WTC collapse.
17 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗AMBIENT AIR SAMPLING REPORT for Rector Street site; sampling dates in Sept/Oct 2001.
NYC-WTC_000419770–000420230OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC ASSOCIATES INC. - TEM ANALYSIS LAE GROUP #: 5579 - 09/29/01
Filter Type MCE 25 mm Operator Lab Sample No. 59745
Client Spl. No. T22 Filter Area 385 mm^2
Grid I.D. Disk No. Instrument I.D. EM lU CNN (GOI Area 0.01124 mm"2 Comments Screen Magnification :6,400:{ NO. GO Co be Analyzed 6 ( 4.721 Struct. Corspd. to 70 s/m2. ( Ace. Voltage 80 kV
I.D. of Structure EDS Structure Structure Type Length N or l/ GO. (Nonasb. >0.5 um No Coord. No. F H C M <5um > 5urn Chrys. Y Amphibole Nonasb. Ambig./ND Amg✓ Elements)
--- ------------- - --------------- i t..re sll .... Tessa Led anectra— Photo No. (from 1 in 5 aebestos— identify all structures using containin g samples) Grid acceptance: structures u to Ins trim (l <5O%undaolver?itEii. overlapped or folded Struct. _ > 0.5um h > 5:1 Aspect Ratio <10% particulate coverage >50% coverage Totals unfolded or overlapped grid square. U N= Not Observed (EDS spectrum or diffraction pattern) at least 20 <5% holes or opaque areas P 15 U m . ju Positive diffraction pattern propertlee conforming to laboratory Identification criteria observed. Unused portion f -1 For chrsoLils: 0.73nm acing for (020) rs0ectiam, of filter Chrysotile 0.53nm yspacing for than layer line repast, streaking Avoided portion of (110) and (130) reflecLiom. of filter 1toter (2mm wide) For amphiboles: O.S3nm layer Ilne rape►[ and approx. POr~object Amphibole Li 3.5 ratio of non—twinned layer line spot spacing to examination layer line repeat distance (0.53nm). _1 1/= EDS spectrum conforming to laboratory AMPHIBOLES Ambiguous identification criteria observed. Arnooito F= Single Fiber (1-3 intersections = 1-3 fiber.) ~.. _1 S= Bundle (2.3 fibers <1 fiber diameter apart) 25mm filter Crocidolite Non —asbestos C= Cluster (>3 intersection) suipping Ruler. Anthophyilite M= Matrix >50 s/G.D. or in let 4 CA. Tremohte _ 7 NSD= No structure. Detected Non —Identified Actinolite L\DATA\PRIVATa\MIKEG\CA➢D\T£M3 0/22/08
CITY 21MC100 004915884
NYC-WTC 000419830
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000104027
Summary of ambient air sampling and visual observations at 105 Duane Street following the WTC collapse.
17 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329958
Summary and conclusion of TEM results for Man Tech project.
11 shared non-person entities · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000104321
Second volume of ambient air sampling and visual observation results for 105 Duane Street after the WTC collapse.
14 shared non-person entities · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000106077
Chain of custody documentation for background sampling including asbestos and lead at 250 Broadway in September 2001.
11 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237389
Laboratory report documenting transmission electron microscopy results for asbestos fiber analysis at 40 Rector Street floors 16-18.
7 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237252
Laboratory report documenting transmission electron microscopy analysis of air samples from floors 12 and 14 at 40 Rector Street.
7 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237472
Laboratory report documenting asbestos fiber analysis by TEM for an air sample from 40 Rector Street collected on October 23, 2001.
7 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237385
Laboratory report documenting transmission electron microscopy results for asbestos fiber analysis at 40 Rector Street floors 16-18.
7 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000105975
Summary of transmission electron microscopy results for asbestos samples from 250 Broadway dated September 16, 2001.
6 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000174866
Laboratory data sheet documenting asbestos fiber counts from air samples collected on floors 15 through 17.
5 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237327
Laboratory report page containing specific air volume and sample identification data for transmission electron microscopy asbestos fiber analysis at 40 Rector Street.
7 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000174896
Laboratory report detailing asbestos fiber analysis by TEM for samples from floors 16-18 at 40 Rector Street collected October 19, 2001.
5 shared non-person entities · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000270472
TEM analysis of lab sample from New Stuyvesant HS exterior/interior, Oct 2001, under AHERA methods.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244482
TEM analysis of NSHS-FIR-10/13-06 sample, structure details included.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000174856
Detailed technical data sheet for transmission electron microscopy analysis of air sample 59761 from the September 2001 monitoring campaign.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000270446
TEM analysis parameters; NSHS-EIR-10/14-06; interior area, 395 mm2.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000292779
TEM analysis of air samples from New Stuyvesant High School exterior/interior areas by ATC Associates.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000244459
TEM analysis data for a lab sample; building/site unspecified, date Oct 2001.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000104027
Summary of ambient air sampling and visual observations at 105 Duane Street following the WTC collapse.
Similar indexed content
Summary and conclusion of TEM results for Man Tech project.
Similar indexed content
Second volume of ambient air sampling and visual observation results for 105 Duane Street after the WTC collapse.
Similar indexed content
NYC-WTC_000106077
Chain of custody documentation for background sampling including asbestos and lead at 250 Broadway in September 2001.
Similar indexed content
NYC-WTC_000237389
Laboratory report documenting transmission electron microscopy results for asbestos fiber analysis at 40 Rector Street floors 16-18.
Similar indexed content