Inc. ATC Environmental, 25th Street LJ 104 East 10010 New York, New York ELAP #10879 P. Approved N.Y. State Code # 1187 L ATC Associates Inc. ACCREDITED NVLAP Lab 01 104 East 25th Street Report Date: 10/23/ New York, NY 10010 TRANSMISSLUIN Spectroscopy (EDS) ANALYSIS BY ASBESTOS FIBER AN and Dispersive X-RAY Electron Diffraction (SAED) 1987 Identification by Selected-Area ENorgli0, October 30, With Fiber 763), Vol. 52, Register (40 CFR, Part EPA Federal [, Method: SERA Final Rule,

~ Analysis Parameters identification fl Sam le TEM Sample No.: 5741 NY II J Project/Site: 40 Rector Street. Rector St. NY

14 15 19 Analyzed: e Floors 1-12 Grid Openings r"1 Received: 10 23 Ol Li Date Average Grid Opening:_ O0_ Um 106'

project Sample No.: 44-8 Total Area Analyzed:_ 0.04 _5 i0 m2

te.rs Air Volume:_ 180 _0 il ._mmO Analytical Sensitivity:__ 22

diam. Pore Size: 0.45 um { Filter Type: MCE 25 mm j, Effective Area: 385 mm2

ANALYZED CONCENTRATION FIBROUS PARTICULATES Number Obse ed Tota 1 Al r Filter Matrix Total. Struct. Struct/cc ngm/m3 Single Struct/mm2 Struct. >=5um Clusters Struct. Fibers Bundles 0.0000 0 0 0 0.0 0 0 0 Chrysotile Asbestos 0 0 0 0 0 0.0 0.0000 0 o 0 Amphibole Asbestos 0 0.0 0.0000 0 0 0 0 0 0 Ambiguous 0 0.0 0.0000 0 0 0,0 0.0000 N/A ambiguous structures) 0 Total asbestos (includes 0 0 N/A 0 0 0.0 0.0000 Non-Asbestos 0 0 0 0 0 0 0 ' No Identification o .Daoe N/A D o 0.0 Totals (All Structures) deviation. analysis is 1 standard uncertainty of this The estimated ----------------- - _. SAED) None detected -----------" Non- asbestos fiber i.d. (EDS None detected Amphibole Asbestos Type: ------------ method. ---------------------------------- with e approved TEM method carried °lianceawithdtheequalityhspecified for the The Analysis was in comp p. This laboratory is

Report Reviewed by: Analyzed by: sa Ph.D. Michael A. Gorycki, Microscopy Electron Roman Peysakhov Director of

CITY 21MC100 004916 157

NYC-WTC 000420103

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000420103Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000329958

Summary and conclusion of TEM results for Man Tech project.

Similar indexed content

Compare copies and versions →