n L ATC Environmental, Inc. rn 104 East 25th Street New York, New York 10010

ATC Associates Inc. Approved N.Y. State ELAP #10879 104 East 25th Street ACCREDITED NVLAP Lab Code # 1187 New York, NY 10010 Report Date: 10/23/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

~~. Sample Identification Analysis Parameters

Project/Site: 40 Rector Street, 40 Rector St., NY, NY TEM Sample No.: 5741 - 61967

Floors 1-12, 14, 15, 19 Date Received: 10/23/01 Grid Openings Analyzed: 4

r I Project Sample No.: 08-19 Average Grid Opening: 106.00 um

Air Volume: 1830 liters Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity: 22.2 s/mm2

Effective Area: 385 mm2 0.0047 s/cc

1 r ---------------------- -------------------------------------------------------------------------------------------------- FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air

Fibers Bundles Clusters Struct. Struct. >=5um Struct/mm2 Struct/cc ngm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

-, Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0

Non Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A

No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 3.0 0.0000 N/A

The estimated uncertainty of this analysis is 1 standard deviation. .. --------------------------------------- ---------------------------- — ------------------------------------------------------------ Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected ---------------------------------------------------------------------------------------------------------------------------------- ('~ The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

:U Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

iAi

CITY 21MC100 004916124

NYC-WTC 000420070

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000420070Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000329958

Summary and conclusion of TEM results for Man Tech project.

Similar indexed content

Compare copies and versions →