NYC-WTC_000104027
Summary of ambient air sampling and visual observations at 105 Duane Street following the WTC collapse.
17 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗AMBIENT AIR SAMPLING REPORT for Rector Street site; sampling dates in Sept/Oct 2001.
NYC-WTC_000419770–000420230OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC ASSOCIATES INC. - TEM ANALYSIS LAD GROG? #: 5573 - 09/28/01
Lab Sample No. 596_9 Filter Type MCE 25 mm Operator
Client Spl. No. 03 Filter Area 385 mm"2 Instrument ID. EM 10 CRX Grid I.D. ') z~ ! Disk No.
Screen Magnification 16,400K (GO) Area 0.01124 mm'2 Ccmments
Acc. Voltage 80 kV No. 30 tc be Analyzed G ( 4.721 Struct. Corsnd. to 70 s/mm'2.)
Structure Type Length LD. of Structure Nor/ EDS GD. Structure (Nonasb. No Coord. No. F B C M < 5 m > 5urn Chrys. Amphibole Nonasb. Ambig./ND Elements ( V 1f 2-2- 'r G /1
-rnoeo rto. tzrom i in o aeueaLca- ,.a... .. .-....-_ ...... -' _.. .-. ---- - containing samples) Grid acceptance: structures up to 700 rim, (tat 4) <50% undiaaolved (lIter, overlapped or (olded Struct. _ > 0.5um de > 51 Aspect Ratio <10% particulate coverage >50% coverage Totals N= Not Observed (EDS spectrum or diffraction pattern) at least 20 unfolded or overlapped grid square, <5X holes or o a ue areas F Ii U M > 5um v= Positive diffraction pattern properties conforming Unused portion to Laboratory Identification criteria observed. For chrysatila: 0.73nm spacing far (020) reflections, of filter Chrysotile O.S11nm apseing for the layer line repast. streaking Avoided portion of (110) and (1311) reflection.. of filler For amphiboles. 0.59nm layer line repeat, and approx. fester (2mm wide) o; ratio of non-twinned layer Itne spat spacing to Portio act Amphibole P examination layer line repeat distance (0.59nm).
EDS spectrum conforming to laboratory Ambiguous Identification criteria observed. F= Single Fiber (1-0 lhtereeetione = 1-3 fibers) H= Bundle >3 fibers <1 fiber diameter apart) 25mm filter Non —asbestos X Cluster >9 Intersections) C= Stopping Rules: 7Arithophy e = Watrix - ./O.O. or in fat {' G.O. >50 NSD= No Structures Detected Non —Identified L•\DATA\P1lVATIf\M1lEC\CADD\TEa9 0/22/90
CITY 21MC100004915984
NYC-WTC 000419930
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000104027
Summary of ambient air sampling and visual observations at 105 Duane Street following the WTC collapse.
17 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329958
Summary and conclusion of TEM results for Man Tech project.
11 shared non-person entities · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000104321
Second volume of ambient air sampling and visual observation results for 105 Duane Street after the WTC collapse.
14 shared non-person entities · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000106077
Chain of custody documentation for background sampling including asbestos and lead at 250 Broadway in September 2001.
11 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237389
Laboratory report documenting transmission electron microscopy results for asbestos fiber analysis at 40 Rector Street floors 16-18.
7 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237252
Laboratory report documenting transmission electron microscopy analysis of air samples from floors 12 and 14 at 40 Rector Street.
7 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237472
Laboratory report documenting asbestos fiber analysis by TEM for an air sample from 40 Rector Street collected on October 23, 2001.
7 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237385
Laboratory report documenting transmission electron microscopy results for asbestos fiber analysis at 40 Rector Street floors 16-18.
7 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000105975
Summary of transmission electron microscopy results for asbestos samples from 250 Broadway dated September 16, 2001.
6 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000174866
Laboratory data sheet documenting asbestos fiber counts from air samples collected on floors 15 through 17.
5 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237327
Laboratory report page containing specific air volume and sample identification data for transmission electron microscopy asbestos fiber analysis at 40 Rector Street.
7 shared non-person entities · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000174896
Laboratory report detailing asbestos fiber analysis by TEM for samples from floors 16-18 at 40 Rector Street collected October 19, 2001.
5 shared non-person entities · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000340214
TEM analysis records, lab group 5606, Oct 04, 2001 for NYU Trinity project.
Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237399
Detailed transmission electron microscopy data sheet for asbestos fiber identification at 40 Rector Street dated October 19, 2001.
Similarity score 0.983 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248532
TEM analysis report with sample, area, voltage and structure correlation.
Similarity score 0.983 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248508
TEM analysis with EDS/SAED for SHG samples, documenting structure and composition.
Similarity score 0.981 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000248554
TEM analysis with specimen and area measurements; structure ID.
Similarity score 0.981 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000237401
Laboratory report documenting transmission electron microscopy analysis of a sample for asbestos fibers dated October 19, 2001.
Similarity score 0.980 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000104027
Summary of ambient air sampling and visual observations at 105 Duane Street following the WTC collapse.
Similar indexed content
Summary and conclusion of TEM results for Man Tech project.
Similar indexed content
Second volume of ambient air sampling and visual observation results for 105 Duane Street after the WTC collapse.
Similar indexed content
NYC-WTC_000106077
Chain of custody documentation for background sampling including asbestos and lead at 250 Broadway in September 2001.
Similar indexed content
NYC-WTC_000237389
Laboratory report documenting transmission electron microscopy results for asbestos fiber analysis at 40 Rector Street floors 16-18.
Similar indexed content