Ambient air sampling report, Rector Street

Machine-extracted title · confidence 28%

AMBIENT AIR SAMPLING REPORT for Rector Street site; sampling dates in Sept/Oct 2001.

NYC-WTC_000419770–000420230
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC ENVIRONMENTAL, INC APPROVED NY STATE DOH FLAP # 10879 104 East 25th Street ACCREDITED NVLAP Lab Code # 1187 New York, NY 10010

Summary of TEM Results

ATC Associates Inc. DATE: 09/28/01 104 East 25th Street New York, NY 10010 Mr. Scott Graber - -

Project/Site Identification: 40 Rector Street, NY, NY - Floors 5-7 CONCLUSION: ------------------------------------------------------------------------------ STATISTICAL SUMMARY

1) Inside Samples Asbestos Concentration TEM# Project # Volume (1) S/nun^2 S/cc nqm/m"3 5573- 59619 03 1250 0.0 0.0046 5573- 59620 04 1250 14.8 00046 5573- 59621 05 1250 14.8 0.0046 5573- 59622 06 1250 0.0 0.0046 5573--59623 07 1250 0.0 0.0046 5573- 59624 08 1250 0.0 0.0046 5573- 59625 14 1300 0.0 0.0044 5573- -59626 15 1300 0,0 - 0.0044 5573- 59627 16 1300 0.0 0.0044 * - 5573- 59628 -17 1300 89.0 0.0263 5573- 59629 18 1310 29.7 0.0087 Average= 13.5 0.0069 133 2) Outside Samples Asbestos Concentration TEM# Project # Volume(1) S/mm*2 S/cc ngm/m"3 J Average= L NL N/A 3) Blanks Asbestos Concentration TEM# Project # S/mm^2 S/cc ngm/m*3 5573- 59617 01 - - - - - - - - - Not Analyzed - - - - - - - - - U. 5573- 59618 02 - - - - - - - - - Not Analyzed - - - - - - - - - - Average= N/A N/A N/A 4) Value of T - Statistic : N/A J * None detected; concentration equivalent to analytical sensitivity assigned. -I- ---------------------------------------------- ----- ------------------------------------------------------------------------- This test-report relates only to the specific items cited in the analysis. - The analysis was carried out according to the approved TEM method. The laboratory is in compliance with the quality —p specified for the method.

J This report must not be used by the client to claim product endorsement by NVLAP or any agency of the U.S. Government.

Analyzed by: Michael A. Gorycki, Ph.D. n. Roman Peysakhov Director of Electron Microscopy -1

CITY 21MC100 004915972

NYC-WTC 000419918

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000419918Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000329958

Summary and conclusion of TEM results for Man Tech project.

Similar indexed content

Compare copies and versions →