NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 9 pages

Chain of custody, PS 234M dust sampling

Machine-extracted title · confidence 28%

Dust, bulk and ambient air sampling chain-of-custody for asbestos at PS 234M.

NYC-WTC_000419745–000419753
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 2Sth Street New York. New York 10010 I , I 4-j /Ltj www.aec-enviro.com P be/'JYvCLZltVV\ 212 353.8280 I J Fax 212.353.8306 ASSOCIATES

I October 3, 2001 I Mr. Bernard P. Orlan New York City Board of Education I 28-11 Queens Plaza North Long Island City. NY 11101

Rc: Dust, bulk and ambient area air sampling for asbestos at P.S. 234iVI

Dear Mr. Orlan:

At yotir request, ATC Associates, Inc. representatives Mr. Andreas C. Andreou (NYC-DEP asbestos investigator f826S3 & NYS-DOL asbestos inspector / air sampling technician certificate MH 93-1S603), Mr. Yiannis Etstathiou (NYC-DEP asbestos investigator #82244 & NYS-DOL asbestos inspector / air sampling teclinician certificate #AH 96-10905) and Mr. Wagdi Abdelshahid (NYS-DOL asbestos inspector certificate #AH01-02278) visited P.S. 234M located al 292 Greenwich Street, New York, NY 10013 on October 2"f 2001. The purpose of the site visit was to perform a dust and ambient area air sampling to be analyzed for asbestos content throughout the interior of the school building and bulk sampling of debris on the roof as per a NYC-BOE representative.

As per NYC-BOE representative request, a total of fifty (50) dust samples, using 3M scotch tape and a glass slide, and twenty (20) ambient area air samples were collected throughout the school building. Also, three (3) debris bulk samples were collected from the roof.

Also as per the NYC-BOE representative request, all twenty (20) ambient area air samples were analyzed utilizing Transmission Electron Microscopy (TEM). .Analytical results indicated that none of the collected ambient area air samples contain any asbestos structures. See attached laboratory report and results.

All fifty (50) collected dust samples and the three (3) bulk samples were analyzed utilizing Polarized Light Microscopy (PLM).

Analytical results indicated that none of the collected dust samples contain any asbestos fibers.

Analytical results also shown that two (2) out of the three (3) debris bulk samples collected from the roof contain only traces of asbestos.

The dust, bulk and ambient area air sampling performed was limited to testing for asbestos in the locations indicated by aNYC-BOE representative.

CITY_21MC100_003208718

NYC-WTC_000419745

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000419745Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Bulk sample chain of custody form, Sept 2001

NYC-WTC_000182525

Documentation form recording the collection, handling, and transfer of bulk material samples for asbestos analysis at a high school site.

Similar indexed content