NYC-WTC_000233911
Memorandum from NYC DEP describing the monitoring of ambient outdoor air for asbestos in October 2001.
5 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗Lab report describing ambient outdoor asbestos monitoring methods and TEM analysis plans, referencing standards and persistence of asbestos in air.
NYC-WTC_000419704
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
FROM: Kelpin, Gerry
TO: Raffo, Barbara
COPIED:
BCC:
DATE: 20011004 19:47:14
SUBJECT: FW: Web site text
fvi
From: Laduca, John Sent: Thursday, October 04, 2001 6:25 PM To: Kelpin, Gerry; Kelpin, Gerry 001 Subject: Web site text
NYC DEP is monitoring the ambient outdoor air for asbestos. This effort is augmenting ambient air asbestos sampling being done by USEPA and other state and city agencies. There is currently no out door ambient standard for asbestos. The U.S. and NYC standard for asbestos in community and residential buildings is 0.01 fibers/cubic centimeter (f/cc) in indoor air. ..An indoor area which has had asbestos detected and then removed must show that air samples are at or below the 0.01 f/cc standard before the indoor area can be re-occupied. Although we are monitoring the ambient outdoor air, we are using this value as a way to characterize the levels of asbestos in the air. Since the measurement protocol used, phase contrast microscopy (PCM), counts fibers, we are doing an additional analysis for all samples that are above 0.01 f/cc. This measurement protocol is called transmission electron microscopy (TEM) and counts the number of asbestos fibers in the sample. Our TEM results will be added shortly. EPA is reporting their data in TEMs. Results indicate that, as expected, asbestos is present in some of the debris at the site and in areas very close to the site. .As of September 28, 2001, most air sampling results outside the security zone were below the standards for asbestos in indoor air. -As testing continues, there may be the possibility of occasional short-term increases in levels of asbestos in the air above the residential standard of 0.01 fibers per cubic centimeter of air. When the measured level for the out door ambient air is above .01 f/cc, the samples will be analyzed to determine how many of the fibers are actually asbestos fibers.
John LaDuca NYC Department of Environmental Protection Public Affairs - New Media Communications nyc.gov/dep
CITY_21MC100_003206498
NYC-WTC_000419704
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000233911
Memorandum from NYC DEP describing the monitoring of ambient outdoor air for asbestos in October 2001.
5 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000331188
DEP report describing ambient outdoor asbestos monitoring after WTC disaster.
5 shared non-person entities · 1 shared topics · similarity 0.944
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000290273
DEP report describing outdoor ambient asbestos monitoring in Lower Manhattan.
4 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318180
DEP ambient air monitoring in Lower Manhattan; overview of asbestos air sampling program and standards.
5 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275356
DEP outline of ambient outdoor asbestos monitoring and indoor standards reference.
5 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318287
Report on ambient air asbestos monitoring in Lower Manhattan by NYC DEP/related agencies.
4 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321959
DEP report describing ambient asbestos monitoring and indoor standard references for re-occupancy.
4 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121065
Summary of air and dust sampling results collected from private residences and common areas at 250 South End Avenue.
4 shared non-person entities · 1 shared topics · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275354
DEP overview page on ambient outdoor asbestos monitoring in Lower Manhattan and guidance standards.
5 shared non-person entities · 1 shared topics · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000455321
DOH letter explaining asbestos test results in lower Manhattan residences.
5 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436681
DOH letter explaining asbestos results around a Lower Manhattan building, 2002.
4 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000455708
DOH asbestos testing results letter for a lower Manhattan building after WTC collapse.
4 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000233911
Memorandum from NYC DEP describing the monitoring of ambient outdoor air for asbestos in October 2001.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000205183
Overview document from the NYC Department of Environmental Protection explaining ambient outdoor air asbestos monitoring protocols in Lower Manhattan.
Similarity score 0.985 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000290273
DEP report describing outdoor ambient asbestos monitoring in Lower Manhattan.
Similarity score 0.985 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362835
Summary of ambient asbestos air monitoring in Lower Manhattan; no indoor standard established.
Similarity score 0.985 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318180
DEP ambient air monitoring in Lower Manhattan; overview of asbestos air sampling program and standards.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000150106
DEP report explaining ambient air monitoring for asbestos and the use of indoor standards to characterize outdoor levels.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000233911
Memorandum from NYC DEP describing the monitoring of ambient outdoor air for asbestos in October 2001.
Similar indexed content
DEP report describing outdoor ambient asbestos monitoring in Lower Manhattan.
Similar indexed content
DEP ambient air monitoring in Lower Manhattan; overview of asbestos air sampling program and standards.
Similar indexed content
NYC-WTC_000275356
DEP outline of ambient outdoor asbestos monitoring and indoor standards reference.
Similar indexed content
NYC-WTC_000318287
Report on ambient air asbestos monitoring in Lower Manhattan by NYC DEP/related agencies.
Similar indexed content