NYC 9/11 Public Portal Document
NYC Response
Asbestos Air Sampling Resuits at Fixed Locations Data VaUdatlon Date; 03/C3;20C2
Sampiing Date and Time: 2/27/20020001 to 1200
PCM by NiOSH 7400 TEM ( AHERA) PCM fibers
Sampiing Sampling Sample Structures (#)
Dats Sample No. Location Voiume* Matrix f/mm” f/cc O.Sjl - Sp 5p S/mm” S~f/cc‘*
02/27/02 FB022702 Field Blank 0 Air <7.0 n/a NA<^> NA<=^> NA’”’ NA’”’
02/27/02 TB022702 Trip Blank 0 Air <7.0 n/a NA<=^> NAP’ NA<=^’ NA<=^’
02/27/02 TTW-00949 L 1063.3 Air <7.0 <0.003 0 0 <13.12 <0.0048
02/27/02 TTW-00950 Mf 1046.1 Air <7.0 <0.003 0 0 <13.12 <0.0048
02/27/02 TTW-00951 N 1051.2 Air <7.0 <0.003 0 0 <13.12 <0.0048
02/27/02 TTW-00952 J 1103.6 Air <7.0 <0.002 0 0 <13.12 <0.0046
02/27/02 TTW-00953 Q 1116 Air <7.0 <0.002 0 0 <13.12 <0.0045
02/27/02 TTW-00954 Q-Dup 1107.15 Air <7.0 <0.002 0 0 <13.12 <0.0046
02/27/02 TTW-00955 F 1052.7 Air <7.0 <0.003 0 0 <13.12 <0.0048
02/27/02 TTW-00956 A 1036.2 Air <7.0 <0.003 0 0 <13.12 <0.0049
02/27/02 TTW-00957 B 1188 Air <7.0 <0.002 0 0 <13.12 <0.0043
02/27/02 TTW-00958 C 1082.9 Air <7.0 <0.003 0 0 <13.12 <0.0047
02/27/02 TTW-00959 D 1062.4 Air <7.0 <0.003 0 0 <13.12 <0.0048
02/27/02 TTW-00960 K 1097.6 Air <7.0 <0.003 0 0 <13.12 <0.0046
02/27/02 TTW-00961 U 1168.2 Air <7.0 <0.002 0 0 <13.12 <0.0043
02/27/02 TTW-00962 U-Dup 1126.4 Air <7.0 <0.002 0 0 <13.12 <0.0045
02/27/02 TTW-00963 V 1019.7 Air <7.0 <0.003 0 0 <13.12 <0.0050
02/27/02 TTW-00964 S 1009.05 Air <7.0 <0.003 0 0 <11.25 <0.0043
02/27/02 TTW-00965 W 1037.85 Air 10.19 0.004 0 0 <13.12 <0.0049 8
02/27/02 TTW-00930 W 1002.6 Air 30.57 0.012 0 0 <11.25 <0.0043 24
02/27/02 Air <7.0 <0.002 NA»> NAP’ NA® NAP’
02/27/02 Air <7.0 <0.002 NA<” NA<” NA<” NA<”
No sample taken for Location E, due to pump fault
Sampling Locations: Key;
A: NE corner of West Broadway & Barclay M: Western end of Harrison St. at West St. * Sample volumes (liters) are below
B: SE corner of Church & Dey St. (on tree next to bulkhead) recommended limit for the TEM method; volume is
C: Trinity (a.k.a. Church) & Liberty M1 : West St. - 50 yards south of Harrison St. at bulkhead based on pump reading
C1: SW corner of Broadway & Liberty St. N: South side of Pier 25 (next to volleyball ct) ** Structure (S) is roughly equivalent to fiber (f)
D: East end of Albany St. at Greenwich St. P: NE corner of South End Ave. & Albany *** Chrysotile
E: Western end of Liberty St. at South End Ave Q: Barclay & West St. (center island) in **** Extremely low sample volume collected
F: Northern median strip of Vesey & West St proximity to USCG command post ***** Amosite
G: Church and Duane St. R: TAGA Bus Location NAh’ - Not analyzed due to overloading of
H: South side of Chase Manhattan Plaza at Pine St. S: Rector & South End particulates
I: SE corner of Wall St. & Broadway T: Pier 6 Heliport NA® - Not analyzed for TEM
O J: NE corner of Warren & West St. U: Pier 6 Exit 2 n/a - Not applicable
H K: West St. & Albany in median strip V: Pier 6 Bus Sign NR - Not requested
l"^ L: On walkway toward North Park rec area (north side W: Wash Tent Common Area NS - Sample not submitted
to of Suyvesant High), access to TAGA bus area
S NiOSH 7400; Fiber Analysis of Air Samples via NiOSH 7400, Revision 3, issue 2, 8/15/94
O
Asbestos Fiber Analysis by Transmission Eiectrors Microscopy (TEM) EPA 4QCFR Part 763 (AHERA)
o
o Standard criteria; EPA 40CFR Part 763 (AHERA); 0.01 fiber/cc (PCM), 70 S/mm", volume 1200 L, for 25 mm filter (TEM)
I
o
o Ln
to
Ui
co
o
Cn
NYC-WTC_000419550
OCR can misread numbers and units. Confirm readings against the page image before using them.