NYC 9/11 Public Portal Document
Other Compounds
All test results below provided by US EPA
Lead in ambient air: Four samples in hot zone were collected. Highest was 1.9 micrograms per cubic meter. Other samples <1.5 micrograms per
cubic meter (National Air Quality Standard), OSHA PEL is 50 micrograms per cubic meter.
Interpretation: Lead levels in ambient air well below levels for worker concern. Personal monitoring pending.
Volatile organic compounds in ambient air: 3 samples were collected around the debris pile. Low levels of VOCs, no immediate health concerns.
2 samples were collected in the plume - Benzene detected at 100 parts per billion, just at OHS A PEL.
Interpretation: VOC exposures for most workers should be low, but potential exposures exist. Appropriate respiratory protection should continue
to be worn.
Miscellaneous toxic and acid gasses (by direct reading instruments): low levels of phosgene and hydrogen cyanide present.
Interpretation: No immediate public or occupational health threat. Personal air sampling pending. Appropriate respiratory protection should
continue to be worn.
o
H
S
o
I—i
o
o
I
o
o
Oh
Draft: 9/20/01 \MatteSummary_9_20 Page: 3 of 3
Oh
di^
NYC-WTC_000419340
OCR can misread numbers and units. Confirm readings against the page image before using them.