TEM Asbestos (air) Count Sheet Client Name: NYC BOE Volume (liters): 1805 Lab Group #: 6638 Filter Type / Filter Area: MCE 385 mm- Lab Sample #: 2 Grid Opening Size: 0.01124 Client Sample #: 05 Area Examined: 0.04496 mm- GRID BOX: JO: Magnification: 20,000 GRID ID: Accelerating Voltage: too KeV # Grid Openings: 4 Analysis Date: 2/11/02

Analysis Performed By: ROMAN PEYSAKHOV

GO. Structure Structure Type Length ID of Structure N or -i EDS No (Nonadb C M >=05 p Chrys Amphibole Nonasb Ambig/ND No Coord <51J Elements)

Struct = > 0.5p >5:1 Aspect Ratio Grid acceptance: V= Positive diffraction pattern properties conforming to <50% undissolved filter, overlapped or folded Totals laboratory identification criteria observed <10% particulate coverage >50% coverage ate least 20 unfolded or overlapped grid squares <5% F B C M >5u '/= EDS spectrum conforming to laboratory holes or opaque areas identification criteria observed Chi-ysotile AMPHIBOLES Amphibole F = Single Fiber Amosite B = Bundle (<3 fibers <1 fiber diameter apart Crocidolite Ambiguous C = Cluster (>3 Intersections) Anthophyllite Non-Asbestos Tremolite M = Matrix Non-Identified Actinolite NSD = No Structures Delected

CITY_21MC100_010190707

NYC-WTC_0004 18953

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418953Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →