NYC-WTC_000304170
Draft NYC DOH environmental monitoring for WTC-related fibers and routine TEM tracking; chain-of-custody header.
18 shared non-person entities · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗Draft NYC DOH environmental monitoring document relating to WTC collapse exposure fibers.
NYC-WTC_000418628–000418684OCR status: ok · source: pdftotext
or fields examined by the microscopist. Appendix G presents calculations that estimate the target volume of air needed for each activity scenario, assuming the goal is to be able to quantify cancer risk at the 1 E-04 level, and assuming that 50 TEM grid openings or 100 PCM fields will be evaluated. The precise combination of flow rate and sampling time needed to approach or exceed these target volumes will be selected by the field teams based on the specific requirements for each scenario.
We suggest that at least 8-12 individual sites be evaluated for each type of scenario that is investigated (i.e., routine business or household activities, active cleaning of a household or business, active restoration of a residence or facility). The sites chosen for each scenario should also be representative of differing levels of exposure (i.e., dusty vs. non-dusty, asbestos found in dust vs. absent) and locations in proximity to the WTC (i.e., lower floors vs., higher floors, less than a block away vs. greater distances). The following scenarios are suggestions and should be modified to better fit the conditions and situations encountered around the WTC area, as indicated.
Scenario 1: Sampling During Routine Business or Household Activities Eight to twelve residences in the vicinity of the WTC should be selected for sampling during routine household or business activities. To the extent possible, sites chosen should based on the results of previous environmental assessments and asbestos sampling (i.e., dusty conditions, dust samples, IR spectroscopy, air samples) to provide a range of expected conditions and exposures.
Resident and/or business participation in the investigation should be strictly voluntary. Preference should be given to volunteers who are non-smokers, since smoke particles in air collect on filters and could tend to reduce analytical sensitivity of air samples collected.
Air samples for asbestos analysis should be collected using both personal and stationary air sampling pumps.
The personal air sampler will be worn by an adult resident in the apartment or business, who will engage in all normal activities except active cleaning. The participant will need to remain indoors as much as possible throughout the sampling period. As discussed in Appendix G, the target volume of air needed to obtain a detection limit equivalent to a 95% UCL risk level of 1E-04 is quite large (4,900 L for the IRIS method and over 80,000 L for the Berman and Crump method). Thus, every effort should be taken to maximize flow rates and collection times. To this end, collection may be extended across two or more days, if the resident is willing. Due to the presumed length of the sampling period, the sampling team will return to the apartment periodically (about every 4 hours) to ensure the pumps are operating properly. To ensure the battery does not run down c during sampling, the team will change the personal air sampling pump every visit (about CD E 4 hours apart). 3 o o Q The location of the stationary air sampler will be the main living area of the apartment or TO ■c o Q_ work area of the business (see USEPA 2000b). A high volume pump will be used to collect the stationary sample. The sampling time for the stationary air monitor should be sco o o Z o 3 o 0. o' O) O 6 z CITY_21MC100_008907106 z
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000304170
Draft NYC DOH environmental monitoring for WTC-related fibers and routine TEM tracking; chain-of-custody header.
18 shared non-person entities · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000455886
Draft framework for environmental monitoring around WTC collapse, including exposure and fiber metrics.
19 shared non-person entities · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000454763
Draft NYC OEM memo on environmental monitoring for World Trade Center-related exposure.
19 shared non-person entities · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302886
Draft plan for environmental monitoring of exposure to fibers after WTC collapse.
19 shared non-person entities · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407762
Draft NYC EH monitoring document on exposure to fibers after WTC collapse.
18 shared non-person entities · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241981
Final NYC-WTC sampling plan documenting fiber exposure assessments.
19 shared non-person entities · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436795
Draft NYC EH Environmental Monitoring chain-of-custody related to World Trade Center exposure tests.
19 shared non-person entities · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241781
Draft confidential sampling and exposure monitoring plan for WTC debris events.
19 shared non-person entities · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442318
Chain-of-custody outlining indoor and dust sampling protocol for Lower Manhattan residences.
11 shared non-person entities · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149346
A chain of custody cover sheet for air monitoring samples sent to the EPA Region 1 laboratory in January 2003.
14 shared non-person entities · 1 shared topics · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436633
Protocol overview for indoor/dust sampling across 30 Lower Manhattan buildings, Feb 2002.
11 shared non-person entities · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241745
Draft NYC-WTC environmental monitoring sampling plan for fibers and exposure.
18 shared non-person entities · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000241981
Final NYC-WTC sampling plan documenting fiber exposure assessments.
Similarity score 0.978 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000454763
Draft NYC OEM memo on environmental monitoring for World Trade Center-related exposure.
Similarity score 0.974 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000455886
Draft framework for environmental monitoring around WTC collapse, including exposure and fiber metrics.
Similarity score 0.974 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000304170
Draft NYC DOH environmental monitoring for WTC-related fibers and routine TEM tracking; chain-of-custody header.
Similarity score 0.965 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241781
Draft confidential sampling and exposure monitoring plan for WTC debris events.
Similarity score 0.964 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302886
Draft plan for environmental monitoring of exposure to fibers after WTC collapse.
Similarity score 0.964 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000304170
Draft NYC DOH environmental monitoring for WTC-related fibers and routine TEM tracking; chain-of-custody header.
Similar indexed content
NYC-WTC_000455886
Draft framework for environmental monitoring around WTC collapse, including exposure and fiber metrics.
Similar indexed content
NYC-WTC_000302886
Draft plan for environmental monitoring of exposure to fibers after WTC collapse.
Similar indexed content
NYC-WTC_000454763
Draft NYC OEM memo on environmental monitoring for World Trade Center-related exposure.
Similar indexed content
NYC-WTC_000407762
Draft NYC EH monitoring document on exposure to fibers after WTC collapse.
Similar indexed content