OCR text

OCR status: ok · source: pdftotext

stationary or personal air monitors may also be analyzed for a variety of other environmental contaminants (e.g., metals, RGBs).

SECOND OBJECTIVE: PCM vs TEM

Step 1. State the Probiem

The second issue being addressed by this study is that most air concentration data obtained to date at the site are based on PCM and/or TEM measurements, while the current risk assessment method used by EPA for asbestos is based solely on fiber counts measured by PCM. The reasons for this dichotomy are mainly historic: most historic epidemiological studies of asbestos exposure in workers used PCM to quantify asbestos levels in air, and these studies provide the basic dose-response data used by EPA to establish the slope factor for lung cancer. However, PCM is subject to a number of limitations, and it is well recognized that TEM can identify thinner fibers than PCM, and is also able to clearly distinguish asbestos from non-asbestos fibers. For these reasons, TEM is the preferred approach, but an estimate of what the PCM result would be is also needed in order to be able to utilize the current cancer slope factor. Thus, a site-specific empiric conversion factor between TEM and PCM fiber counts is required to allow fiber counts measured by one technique to be extrapolated to the results that would have been obtained by the other technique.

Step 2. identify the Decision

The purpose of this part of the study design is to develop an empiric conversion factor to convert from TEM to PCM fiber counts (and vice versa). No formal decision will be based on this conversion factor. Note that an empiric factor derived for the WTC or at different sites within the WTC vicinity may not be applicable to other sites.

Step 3. identify inputs to the Decision

Data required to establish a site-specific empirical correlation factor between PCM fibers and TEM fibers is an extensive set of samples analyzed by each method. Ideally, this set of samples should span a wide range of fiber concentrations so that the relationship is well constrained over most of the relevant range.

Step 4. Define the Study Boundaries

The bounds of the study are the same as described above.

Step 5. Deveiop a Decision Ruie c CD E 3 No formal decision will be made with the correlation factor derived from this study. o o Q Step 6. Specify Limits on Decision Errors TO ■c co o co co Q_ o o Z o 3 o 0. o' O) O 6 Z CITY_21MC100_008907102 z

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418637Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →