NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 9 pages

WTC World Trade Center health/PM2.5 monograph

Machine-extracted title · confidence 50%

EPA/HMH analyses on PM2.5 toxicity relevant to WTC environmental health effects.

NYC-WTC_000418055–000418063
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mini-Monograph i Chemical analysis of WTC PM; 5

of deionized water and 1 M HCl extracts degrees. Collection software used was Datascan 5 endotoxin units (EU)/ng]. Pieliiiiinaiy inhi­ were measured using ICP-MS and ICP-AES. (version 3.2; Materials Data, Inc., Livermore, bition tests (positive product controls) were The two extraction liquids are used to esti­ CA). Evaluation software was MDI Jade 5 performed on the undiluted samples spiked mate easily bioavailable and total bioavailable using the pattern library Powder Diffraction with CSE equivalent to twice the sensitivity metal content, respectively. Although this File (PDF), release 2000 (International Centre (E; 0.03 EU/mL). The error of the gel-clot speciation scheme i.s a rough approximation for Diffraction Data, Newtown Square, PA). method i.s ± one 2-fold dilution. of bioavailability for PM2.5 samples of com­ Neutron activation analysis. NAA was ICP-MS and ICP-AES. Control PM,.; plex multielemental composition, it has used to determine the total elemental content samples, lyophilized WTC PM2 5 samples, proven useful in characterizing inhalation tox­ of lyophilized WTC and control PM2.5 sam­ and polycarbonate filters taken during the icology end points for various source and ples (NCSU 2002). Samples of these materials inhalation exposure to WTC3 PM2.5 were ambient particulates (Costa and Dreher 1997; (3-7 mg) were packaged in precleaned poly­ extracted with deionized water or 1 M HCl Kodavanti et al. 1998). ethylene vials in a clean hood, and irradiated as and analyzed for their elemental content. Sufficient quantities of MSH, ROFA, and follows. For aluminum (Al), chlorine (Cl), Samples (4-6 mg) were extracted with 1.6 mE pooled WTCX samples were available to per­ copper (Cu), magnesium (Mg), manganese of either liquid. Polycarbonate filters contain­ form all analyses. Quantities of the individual (Mn), sodium (Na), titanium (Ti), and V con­ ing 2-3 mg WTC3 PM2.5 were extracted with site WTC samples and SRM 1649a were very tent, samples were irradiated for 30 sec at 13 mL of either liquid. High-speed centrifuga­ limited (Table 1), and analyses were prioritized < 900 kWtH, decayed for 10-30 min, and tion was used to sepaiate tire liquid and solids to yield the greatest information possible. counted for 5 min. For all other elements, (17,000 for 1.6-mL samples; 51,000 for SEM/EDX testing required < 1 mg and was samples were irradiated for 6 hr at < 900 kWj,,. 13-mL samples). After dilution, extraction solu­ selected for all samples. NAA was chosen as the For arsenic (As), potassium (K), molybdenum tions were analyzed quantitatively using ICP- next most applicable analysis to provide total (Mo), and antimony (Sb) content, samples MS (ELAN 6000; PerkinElmer Instruments, elemental composition data tn support were decayed for 1 week and counted for Shelton, CT) and ICP-AES (Model P40; SEM/EDX. We performed OC/EC/CC, ICP- 15 min each. For Fc, Ni, barium (Ba), calcium PerkinElmer Instruments) as previously MS, ICP-AES, and IC analyses on remaining (Ca), chromium (Cr), strontium (Sr), and zinc described (U.S. EPA 2002f, 2002g, respec­ samples where possible. XRD and XRF analyses (Zn) content, samples were decayed for 2 weeks tively). Filter blanks levels for all elements were performed only on the WTC3 sample. and counted for 30 min each. y-Ray spectra were negligible compared with the levels in the SEM/EDX analysis. SEM/EDX provided were counted and compared against calibration PM samples. physical and chemical characterization of parti­ and quality control standards, and quantitative Ion chromatography of deionized water cles and fibers found in the control samples analyses were performed. extracts. Deionized water extracts from the and lyophilized WTC PM2.5 samples, and on X-Ray fluorescence analysis. Five poly­ ICP sample prep as described above were ana­ PM2.5 on polycarbonate filters taken during carbonate filters (Isopore 0.8 pm, 47-mm lyzed quantitatively for anion and cation con­ the inhalation exposure study using the WTC3 diameter. Millipore Corporation, Bedford, tent using IC (ManTech Environmental, sample. SEM/EDX was cairied out using a MA) loaded with die WTC3 PM2 5 sample, Research Triangle Park, NC). A DX-500 ion Personal SEM (PSEM) (formerly R.J. Lee with five lot-matched blank filters, were chromatograph (Dionex, Sunnyvale, CA) was Instruments, Ltd., now Aspex Instruments, mounted in liquid-type polyethylene sample used with an ASM column (Dionex) for Trafford, PA) as previously described (U.S. cups, placed in a stainless steel sample holder, anion analysis in Suppressor-ASRS Ultra- EPA 2002e). For lyophilized WTC or control and analyzed. X-ray intensities were collected AutoSuppressor Recycle mode, with 3.5 mM samples, a small amount wa.s applied to an with the Philip.s PW2404 XRF (Philip.s Na2CO3/l.0 mM NaHCOj eluent. A CSI2 adhesive carbon tab affixed to an aluminum Analytical, Natick, MA) using the Philips column (Dionex) was used for cation analysis SEM stub. For filter samples, small pieces (< 1 proprietary software SuperQ. Net intensities in Suppressor-CSRS II Ultra-AutoSuppressor cm^) were affixed to aluminum SEM stubs (peak-background) were analyzed using the Recycle mode, with 20 mM methanesulfonic using a carbonaceous suspension. Because only standardless software UniQuant 4 (Omega acid eluent. 15-30 images were examined from each sam­ Data Systems, Veldhoven, the Netherlands) ple, the results should not be interpreted as after subtraction of the intensities due to the Results quantitative or comprehensive (Mamane et al. blank filter system. The constituents of the Analytical chemistry of solid samples. 2001). Rather, these qualitative results were dust were evaluated as oxides. SEM/EDX analysis. Water-extracted and used primarily to determine consistency with Carbon fraction analysis. Carbon specia­ lyophilized WTC PM2.5 samples were domi­ other analytical techniques described below. tion into OC/EC/CC ftactions was performed nated by large snowflakelike crystals com­ X-Ray diffi-action analysis. XRD was used on control and lyophilized WTC PM2 5 sam­ posed of Ca, sulfur (S), and oxygen (O) to qualitatively determine the presence of any ples and on quartz filters taken during the (Figure 3A). Aggregates of fine particles com­ crystalline compounds in the Mn/C3 sample inhalation exposure to WTC3 PM2.5. The posed of various combinations of Ca, Mg, Al, used in the inhalation exposure study. The thermo-optical method, based upon sequential S, O, and silicon (Si) were also prominent PM53 sample was side-drifted into an alu­ pyrolytic vaporization and detection of the (Figure 3B). Fibers approximately 1 pm in minum holder and mounted into the Siemen.s three carbon fractions, was performed (Sunset diameter were found in most of the .sample.s D-500 diffractometer (Brukcr Analytical X- Laboratory, Forest Grove, OR) as previously and had a composition similar to the fine Ray Systems, Madison, WI). The generator, described (Birch and Cary 1996; Sunset 2002). particle aggregates (Figure 3C). Metallic par­ set at 45 kilovolts and 40 milliamperes (mA), Endotoxin analysis. One-milliliter aliquots ticles [mostly Ti and Fe, although Zn, lead generated X-rays from a copper-target X-ray of filter extracts from each individual site sam­ (Pb), Ba, and Cu were also found] were tube. The filament current was 3.46 mA. ple were analyzed for endotoxin content using found typically as inclusions in the large Intensities were collected by a lithium-drifted the limulus amebocyte lysate gel-clot method aggregates of fine particles (Figure 3D). silicon detector fitted with a monochromator (Associates of Cape Cod, Inc., Falmouth, SEM/EDX analysis of the aerosolized riding on a goniometer in the coupled MA). Samples were titered using a 2-fold dilu­ PM2.5 fraction of WTC3 (not water extracted) 0/20 mode, where 0 = diffraction angle. Peaks tion scheme against control standard endo­ showed the same overall chemistry as the were collected in the range 20 = 5 to 85 toxin [CSE; lot no. 85, Escherichia coli 0113, extracted and lyophilized MHC PM samples;

Environmental Health Perspectives • volume 1111 number 7 I June 2003 975

CITY_21MC100_011068670

NYC-WTC_000418058

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000418058Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →