PCM air sample analysis summary, WTC site, Oct 22, 2001
Machine-extracted title · confidence 95%
Riverpoint Consulting laboratory report summarizing personal air sample results for asbestos fibers collected at the World Trade Center site on October 22, 2001.
Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
cnata V^onsulting
c
kJcrviccs, Inc.
304 Edgemont Terrace Teaneck NJ 07666 201 692 7967 fax 201 678 1789
Certificate of Analysis
Client: Riverpoint, Inc Project Location: WTC, NYC Analysis Date: October 22, 2001
Client#: 101171 Work Area: N/A RCS Project# 114
PCM Air Sample Analysis Summary
Lab ID Client ID Sample Description Date Flow Rate Duration Volume Fibers Fields Density Fiber Cone. LOD
Collected [liters/mrn.] [minutes] [liters] [Fiber/mm"] [Fiber/cc] [Fiber/cc]
2876 011022 Park Place and Church 10/22/01 14.50 45 652.5 6.00 100 7.64 0.005 0.004
2877 021022 Park Place and Greenwich__________ 10/22/01 14.50 45 652.5 3.00 100 3.82 <LOD 0.004
2878 031022 Murray and Church________________ 10/22/01 15.00 45 675.0 5.00 100 6.37 <LOD 0.004
2879 041022 Murray and Greenwich_____________ 10/22/01 14.50 45 652.5 5.00 100 6.37 <LOD 0.004
2891 051022 Fulton and Church 10/22/01 15.00 47 705.0 4.50 100 5.73 <LOD 0.004
2881 061022 Warren and North End_____________ 10/22/01 15.00 45 675.0 6.00 100 7.64 0.004 0.004
2880 071022 West Street and Warren____________ 10/22/01 14.50 45 652.5 4.00 100 5.10 <LOD 0.004
2897 081022 Gateway Plaza___________________ 10/22/01 15.00 45 675.0 4.00 100 5.10 <LOD 0.004
2896 091022 South End Avenue and Albany_______ 10/22/01 14.40 47 676.8 5.00 100 6.37 <LOD 0.004
2889 101022 West and Albany_________________ 10/22/01 15.00 54 810.0 7.00 100 8.92 0.004 0.003
2895 111022 Rector Place by park______________ 10/22/01 14.60 47 686.2 8.00 100 10.19 0.006 0.004
2893 121022 3rd Place and West End and Waterside 10/22/01 14.80 46 680.8 10.50 100 13.38 0.008 0.004
2894 131022 West end of West Thames 10/22/01 14.60 47 686.2 4.00 100 5.10 <LOD 0.004
2882 141022 Park Place and River Terrace________ 10/22/01 15.00 45 675.0 5.00 100 6.37 <LOD 0.004
2883 151022 River Terrace and Chambers________ 10/22/01 15.00 45 675.0 3.50 100 4.46 <LOD 0.004
2884 161022 River Terrace and Warren 10/22/01 15.00 45 675.0 2.00 100 2.55 <LOD 0.004
2885 171022 North End and Park Place 10/22/01 15.00 45 675.0 6.00 100 7.64 0.004 0.004
2886 181022 Vesey and River Terrace___________ 10/22/01 14.75 45 663.8 5.00 100 6.37 <LOD 0.004
2890 191022 Trinity Place and Thames___________ 10/22/01 15.00 45 675.0 17.50 100 22.29 0.013 0.004
2892 201022 Vesey and West Broadway__________ 10/22/01 15.00 48 720.0 10.00 100 12.74 0.007 0.004
2887 FBI Field Blank 1_____________________ 10/22/01 0.00 0 0.0 0.00 100 0.00 N/A N/A
2888 FB2 Field Blank 2 10/22/01 0.00 0 0.0 0.00 100 0.00 N/A N/A
o
H
ELAP ID No. 11750 Expires 12:01 AM, April 1, 2002 Analysis Method: Phase Contrast Microscopy, NIOSH Method 7400
NJ
Limit of Quantitation (LOQ) = 102 [Eiber/mm^]
S
o Limit of Detection (LOD) = 7 [Eiber/mm^]
o
o
Io
o
co
Analysis Performed By: A4 ^.24
co Marek Pawlik
co
co Laboratory Director
kD
NO
NYC-WTC_000417573
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000417573Source: NYC Law Department, mirrored locally
Riverpoint Consulting laboratory report summarizing personal air sample results for asbestos fibers collected at the World Trade Center site on October 22, 2001.
Riverpoint Consulting laboratory report summarizing personal air sample results for asbestos fibers collected at the World Trade Center site on October 23, 2001.
Riverpoint Consulting laboratory report summarizing personal air sample results for asbestos fibers collected at the World Trade Center site on October 22, 2001.
Riverpoint Consulting laboratory report summarizing personal air sample results for asbestos fibers collected at the World Trade Center site on October 22, 2001.