NYC-WTC_000366976
PCM microscopy fiber results for 333 Rector Place samples; fiber concentrations reported.
6 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗Ambient air sampling in apartments/common spaces; AH sampling calibrations described.
NYC-WTC_000417246–000417284OCR status: ok · source: pdftotext
ZZ3ZI.M00 OIM-OAN
9f'SSA8800 00TOWT2 XIIO
1^1.220 TEM Asbestos (air) Count Sheet sample area analyzed
Client Name: GCI Environmental Advisory, Inc. Job#: 201101239 Volume flitersl; 1 3.50.0 Lab Sample #: 01 Filter Type/Filter Area: MCE 385 mm2 Client Sample #: 333-9/254 Grid Opening Size; 0.01000 Received: 10/03/2001 14:11:20 Area Examined: 0.10000 nmi2 Date Analyzed: 10/03/2001 Magnification: 20,000 Scope #: Accelerating Voltage: 100 KeV Analysis Performed by: Roman Peysakhov Location Grid Length Width Opening Fiber ;tM gM Fiber 'lypc Morphology EDS Orient. SAED Photo B2-5/1B 1 NSD U B2-5/1C 2 NSD U B2-5/1E 3 NSD U B2-5/1F 4 NSD u B2-5/1G 5 NSD u B3-5/1B 6 NSD u B3-S/IC 7 NSD u B3-5/1E 8 NSD u B3-5Z1F 9 NSD u B3-5/iG 10 NSD u
bJSD: No Asbestos Structures Detected Comments Modified TEM Level II reports only asbestos fibers >-5 microns in length Structure Density Concentration Total Grid Openings: 10 Cstr/ntm2) (sir/cc air) Grid Evaluation Chrysotile Asbestos Structures: 0 <10 <0,0029 13 Grid Openings Covered > .50% Amphibole Asbestos Structures: 0 <10 <0.0029 Intact Grid Opening > 50% Asbestos Structures >=5 microns: 0 <10 <0.0029 [3 Undissolved Filter < 10% Total Non-Asbestos Structures: 3 Folded Replica <50% Total Asbestos Structures; 0 <10 <0.0029 13 Filter Loading < 10% Analytical Sensitivity: 10 0,0029 3 Particulate Even
juaiunooa IBpoj oiiqnj u/e OAN
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000366976
PCM microscopy fiber results for 333 Rector Place samples; fiber concentrations reported.
6 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000366984
PCM microscopy fiber results for Apt. OSS and Apt 08R at 333 Rector Place.
4 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000366972
PCM microscopy fiber results for 333 Rector Place samples; fiber counts and TWA provided.
4 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367150
SciLab PCM fiber results for 22 River Terrace, sample 01/22/01 data.
7 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000366982
Template PCM fiber results for 333 Rector Place with measured fibers per mm2 and per cc.
6 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367146
SciLab PCM fiber results for 22 River Terrace, clearance (Amended 9/29/01).
7 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367153
SciLab PCM fiber results for 22 River Terrace, Rockrose project, 4-page report.
6 shared non-person entities · 1 shared topics · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367157
PCM fiber results report for GCI Inc. at 22 River Terrace, NYC, 2001.
6 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367144
SciLab PCM fiber results for 22 River Terrace, clearance amended 9/29/01.
5 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367167
PCM fiber results report for GCI Inc. at 22 River Terrace, NYC, 2001.
5 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367148
SciLab PCM fiber results for 22 River Terrace, Finals.
6 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120604
Laboratory analysis of ambient air samples collected in September 2001 at 333 Rector Street to detect asbestos fibers.
19 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000367183
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similarity score 0.975 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120604
Laboratory analysis of ambient air samples collected in September 2001 at 333 Rector Street to detect asbestos fibers.
Similarity score 0.975 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120604
Laboratory analysis of ambient air samples collected in September 2001 at 333 Rector Street to detect asbestos fibers.
Similarity score 0.975 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367006
Laboratory bench sheet tallying asbestos structures seen by electron microscope for an air sample; raw counts, not the reported result.
Similarity score 0.975 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120885
Detailed laboratory analysis of ambient air samples collected in September 2001 at 22 River Terrace to assess asbestos contamination.
Similarity score 0.975 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120604
Laboratory analysis of ambient air samples collected in September 2001 at 333 Rector Street to detect asbestos fibers.
Similarity score 0.975 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000366976
PCM microscopy fiber results for 333 Rector Place samples; fiber concentrations reported.
Similar indexed content
NYC-WTC_000366984
PCM microscopy fiber results for Apt. OSS and Apt 08R at 333 Rector Place.
Similar indexed content
NYC-WTC_000366972
PCM microscopy fiber results for 333 Rector Place samples; fiber counts and TWA provided.
Similar indexed content
NYC-WTC_000367150
SciLab PCM fiber results for 22 River Terrace, sample 01/22/01 data.
Similar indexed content
NYC-WTC_000366982
Template PCM fiber results for 333 Rector Place with measured fibers per mm2 and per cc.
Similar indexed content