NYC-WTC_000417978
Bulk sample tracking form including PLM methods and negative/positive counts.
29 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗Copy of environmental hazard assessment reports from JLC Environmental Consultants.
NYC-WTC_000417141–000417245OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document t .-n-L-cc.-j.i ervfsis*.'*.!!-,?!*
- ---
> environmental consul,, “S. INC, 2fc„ i^ark Avenue South, Suite WO1, New York, Mh^.- i'orR 10003 J Phone; (212) dZG-fi 119 Fax: (212) 420-6002 Project No.: 01-2214 WSA Management ELAP Lab Code: 11029 Analyte: FIBERS 1 CO Ring Road West NIOSH and AIHA Lab Code; 100273 Dale Received: 11/16/01 Garden City, NY 11530 HVCj^P Lab Code: 101953 Date Analyzed; 11/16/01 Batch#; 0111 ABU SUMMARY OF ANALYTICAL RESULTS Site; BOJuliii Street, New York, NY
SAMPLE # COLLECTED DESCRIPTION / LOCATION TIMElmin) VOLUME(L) FIB/FIELD RE5ULTS(f/cc) LAB#
007 FIELD BLANK 0/100 16-November A 9208
qoB FIELD BLANK 0/100 le-Novamber A 9209
Sampli Analysis by; <LOD = Less than limit of detection which is 5,5 Fibers/ 100 Fields VOID1 = H.C.P. ( High Concentration of Particles) Positive Phase Contrast Microscopy (PCM) VOID2 = Overloaded Method of Sample Preparation and Analysis: All samples atialyzed In accordance with the HI OSH 7400 Malhod using "A" Counting Rules. Issue 2, August 1904 InEtrumentation: Olympus PCM Model BH-2wltb Wallon-Beokett Graticule (lOOum field diameter). Laboratofy Director Report Date; November 16. 2001 JLC is responsible for only the fiber counts within the iimitations of the method described as NIOSH 7400. Among other limitations, thia meth gives only an index of airborne fibers and provides only an estimate of asbestos concentration. Any and ail claims arising out of JLC's analysi these samples are limited in recovery to the cost of analyzing samples. JLC accepts no other ilabiiily and the client agrees to seek no costs b the above. Page 2 of 2 10532 CITY_21MC100_008875482
NYC-WTC_000417229
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000417978
Bulk sample tracking form including PLM methods and negative/positive counts.
29 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000421430
Detailed chain-of-custody table for bulk and air samples with positive asbestos readings.
30 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000418335
Chain-of-custody for air monitoring samples collected after 2001 event at 21 West Street; references lab results and contractor contacts.
21 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390331
Summary of analytical results for ambient air PCM at 80 [name], New York, Dec 3, 2001.
11 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000416867
Chain-of-custody form for asbestos/air samples from WTC site; includes sample IDs and analytical results.
14 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390325
Memo transmitting lead in air results for 80 [name], New York, Dec 14, 2001.
10 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗18 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000108576
Letter submitting environmental hazard assessment reports from JLC Environmental Consultants to DEP.
20 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000123797
NYC DEP letter to building owner requesting environmental hazard assessments and bulk sample results for WTC-area building re-occupancy.
26 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000094592
Multi-page chain of custody document tracking the handling of samples collected from 21 West Street.
22 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000131928
Fragmented document page from the Department of Environmental Protection archive.
14 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000101024
Automated log record confirming the successful transmission of six pages to the DEP lead tracking unit on April 4, 2003.
15 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000390351
Analytical results for airborne fibers at 80 [name], NY, including lab batch 0111A914.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390307
Summary of analytical results for ambient fiber samples at 80 [name], New York, Oct 2001.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390300
Summary of analytical results for air sampling at 80 [name], NY.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390343
Summary of analytical results for fibers at 80 [name], New York, Oct 2001.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390360
Air and fiber results for 80 [name], NY, including lab details and sample times.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000418335
Chain-of-custody for air monitoring samples collected after 2001 event at 21 West Street; references lab results and contractor contacts.
Similarity score 0.988 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Similar indexed content
NYC-WTC_000108576
Letter submitting environmental hazard assessment reports from JLC Environmental Consultants to DEP.
Similar indexed content
NYC-WTC_000417978
Bulk sample tracking form including PLM methods and negative/positive counts.
Similar indexed content
NYC-WTC_000421430
Detailed chain-of-custody table for bulk and air samples with positive asbestos readings.
Similar indexed content
NYC-WTC_000123797
NYC DEP letter to building owner requesting environmental hazard assessments and bulk sample results for WTC-area building re-occupancy.
Similar indexed content