NYC-WTC_000417978
Bulk sample tracking form including PLM methods and negative/positive counts.
29 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗Copy of environmental hazard assessment reports from JLC Environmental Consultants.
NYC-WTC_000417141–000417245OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
’’ WSA Management JLC Project #01-2214 November 16, 2001 page 2 Air Sampling Analysis and Procedure
Introduction Air sampling is defined as the process of measuring the filter content of a known volume of air entrained on a filter membrane over a specified period of time. Each sample is cross-referenced by field designation and a JLC lab internal code to ensure proper, consistent handling through a chain of custody. Sample preparation takes place within an HEPA filter clean bench to avoid any possible contamination.
Methodology Test procedures for these samples confonn to the National Institute of Occupational Safety and Health (N1O3H) standards.
Air sampling was conducted at a level approximating the breathing zone of persons anticipated to be present in the area during normal operations. Samples collected should represent the area's typical airborne fiber concentration.
All samples were collected on fully exposed 25 millimeter, 0.8 micrometer (pm) cellulose ester membrane air sampling cassettes with conductive cowl.
Analytical Procedures A section of the filter approximating twenty-five percent of the total filter was removed and placed on a pre-cleaned microscope slide and then exposed to approximately 250 microliter (pl) of acetone vapor. A single 3.0 - 3.5 pl drop of triacetin was applied and a clean #1.6 cover slip was placed upon the filter. The prepared slide was then heated on a slide heater until clarity allowed analysis to be conducted.
Analysis was accomplished utilizing a Phase Contrast Microscope in accordance with NIOSH 7400 method, counting rule "A,"
Phase Contrast Microscopy JLC Environmental's laboratory uses an Olympus BH-PC Phase Contrast Microscope, (PCM) equipped with a Walton-Beckett Graticule. Samples were analyzed by first dissolving the filter through a chemical process (described above) and then counting the fibers with PCM at 400x magnification. Phase contrast increases the tight contrast between the object and the background, thus enhancing the microscopist's ability to see fibers. Normally, 100 microscopic fields or 100 fibers are counted, whichever occurs first.
Analytical Results The "Summary of Analytical Results" represents the results of the analysis of the samples. The PCM limit of reliable quantification is less than 0.01 fibers/cubic centimeter (f/cc) of air. If final tests do not meet these requirements, the entire work site must be re-cleaned and re-tested.
CITY_21MC100_008875480
NYC-WTC_000417227
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000417978
Bulk sample tracking form including PLM methods and negative/positive counts.
29 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000421430
Detailed chain-of-custody table for bulk and air samples with positive asbestos readings.
30 shared non-person entities · 1 shared topics · similarity 0.985
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000418335
Chain-of-custody for air monitoring samples collected after 2001 event at 21 West Street; references lab results and contractor contacts.
21 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390331
Summary of analytical results for ambient air PCM at 80 [name], New York, Dec 3, 2001.
11 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000416867
Chain-of-custody form for asbestos/air samples from WTC site; includes sample IDs and analytical results.
14 shared non-person entities · 1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390325
Memo transmitting lead in air results for 80 [name], New York, Dec 14, 2001.
10 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗18 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000108576
Letter submitting environmental hazard assessment reports from JLC Environmental Consultants to DEP.
20 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000123797
NYC DEP letter to building owner requesting environmental hazard assessments and bulk sample results for WTC-area building re-occupancy.
26 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000094592
Multi-page chain of custody document tracking the handling of samples collected from 21 West Street.
22 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000131928
Fragmented document page from the Department of Environmental Protection archive.
14 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000101024
Automated log record confirming the successful transmission of six pages to the DEP lead tracking unit on April 4, 2003.
15 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000390305
Chain of custody for PCM air sampling at 80 [name], NY; signatures and routing.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390358
Chain-of-custody and results for PCM air samples at 80 [name], NY.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390349
Chain-of-custody and results for PCM air sampling at 80 [name], NY, conducted for WSA Management.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390298
Chain of custody for PCM air sampling analysis for 80 [name], NY.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390334
Chain-of-custody documentation for PCM air sampling at 80 [name], New York, Dec 13, 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000108576
Letter submitting environmental hazard assessment reports from JLC Environmental Consultants to DEP.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Similar indexed content
NYC-WTC_000108576
Letter submitting environmental hazard assessment reports from JLC Environmental Consultants to DEP.
Similar indexed content
NYC-WTC_000417978
Bulk sample tracking form including PLM methods and negative/positive counts.
Similar indexed content
NYC-WTC_000421430
Detailed chain-of-custody table for bulk and air samples with positive asbestos readings.
Similar indexed content
NYC-WTC_000123797
NYC DEP letter to building owner requesting environmental hazard assessments and bulk sample results for WTC-area building re-occupancy.
Similar indexed content