NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 105 pages

Chain-of-custody, 80 [name] environmental hazard reports, Feb 2002

Machine-extracted title · confidence 42%

Copy of environmental hazard assessment reports from JLC Environmental Consultants.

NYC-WTC_000417141–000417245
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document . ... . •' '! t /J I

DEC. 3.2001 12:07PM JLC EWIROMMENTRL NO. 157 P.8; I %WSA Management h ■

JLC Project#01-2222 December 3, 2001 page 2 Air Sampling Analysis and Procedure n k r Introduction ...

Air sampling is defined as the process of measuring the filter content of a known volume of air entrained on a filter membrane over a specified period of time. Each sample is cross-referenced by field designation and a JLC lab Internal code to ensure proper, consistent handling through a chain : of custody. Sample preparation takes place within an HEPA filter clean bench to avoid any possible, cxjntamination. j, - E

I Methodology Test procedures for these samples confon|n to the National Institute of Occupational Safety and Health (NiOSH) standards. ’

Air sampling was conducted at a level approximating the breathing zone of persons anticipated to ; be present in the area during normal operations. Samples collected should represent the area’s ’ ■ typical airborne fiber concentration.

All samples were collected on fully exposal 25 millimeter, 0,8 micrometer (pm) cellulose ester membrane air sampling cassettes with conductive cowl. ' i ■ ■' Analytical Procedures A section of the filter approximating twenty-five percent of the total filter was removed and placed oh a pre-cleaned microscope slide and then exposed to approximately 250 microliter (pl) of acetone vapor, A single 3.0 - 3,5 pl drop of triacetih was applied and a clean #1.5 cover slip was placed V upon the filter. The prepared slide was then heated on a slide heater until clarity allowed analysis to be conducted. 4^ Analysis was accomplished utilizing a Pha^e Contrast Microscope in accordance with NIOSH 7400 method, counting rule ’A."

Phase Contrast Microscopy JLC Environmental's laboratory uses an Olympus BH-PC phase Contrast Microscope, (PCWl) equipped with a Walton-Beckett Graticule^; Samples were analyzed by first dissolving the filter through a chemical process (described abpve) and then counting the fibers with PCM at400x cc) p magnification. Phase contrast increases the light contrast between the object and the background, thus enhancing the microscopists ability t© see fibers. Normally, 100 microscopic fields or 100 fibers are counted, whichever occurs first.

Analytical Results ; The "Summary of Analytical Results" represents the results of the analysis of the samples. The; i; PCM limit of reliable quantification is less t'han 0.01 fibers/cubic centimeter (f/cc) of air. If final tests do not meet these requirements, the entire work site must be re-c(eaned and re-tested. /, ■ < I E ; -

10501 E CITY_21MC100_008875451

NYC-WTC_000417198

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000417198Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →