NYC 9/11 Public Portal Document
-tEJlirTTtiaSi
Mr. Nick DcCarlo, CHMM, CPPA
Disaster Response and Recovery
gjjp Station
October 3,2001
Following the O&M clean up, URS collected air samples on each floor of the facility for
subsequent analysis for asbestos, lead, silica, and nuisance dust. The objective of the
monitoring program was to determine tf there were any exceedances of the U.S,
Occupational Safety and Health Administration (OSHA) Permissible Exposure Limits
(PET.) for airborne asbestos, lead, silica, or nuisance dust.
Ail air sampling pumph were calibrated before and after each use. The average flow rate
and total sample time for each sample were used to calculate the total volume of the air
passing through the filter media, and were used in the subsequent concentration
calculations.
Asbestos
Airborne asbestos samples were collected throughout the facility in accordance with
National Institute for Occupational Safety and Health (NIOSH) Method 7402, The
samples were analyzed by Scientific Laboratories (SciLab). SciLab is certified under the
New York State Enviroiunental Laboratory Approval Program (ELAP) to conduct
airborne asbestos analysis by TEM. All airborne asbestos samples were well below the
post-abatement action level of 0.01 asbestos structures per cubic centimeter of air
sampled (s/cc). See Attachment A for the field and laboratory report.
Lead
NIOSH Method 7082 was used by URS for the collection and analysis of airborne lead
samples. This method uses atomic absorption spectrophotomctiy' (AAS) to identify
airborne lead that had been collected on the sample filter. Lead in air samples were
analyzed by ATC Associates in New York City, an American Industrial Hygiene
Association (AIHAj-accredited laboratory. The lead in air concentrations ranged from
<1.7 to 7,8 micrograms per cubic centimeter (pg/nf), which is well below the
Occupational Safety and Health Administration (OSHA) Action Level of 30 pg/m^ and
Permissible Exposure Limit (PEL) of 50 pg/m'’ of air sampled. See Attachment B for the
field data and laboratory report.
Silica and Nuisance Dust
URS perfonned air monitoring for silica and nuisance dust based on NIOSH Method
7500. Silica/nuisance dust samples were analyzed by EMSL Analytical of Westmont,
New Jersey, an AIHA-accredited laboratory. Total silica concentration readings were
less than the detection limit of the analytical method, thus indicating that silica was not
detected. Thus, the OSHA PEL for total silica dust wns not approached or exceeded.
Total nuisance dust ranged from 0.0000 to 0.3556 mg/m’’, well below the OSHA PEL of
5 mg/m^- See Attachment C for the field data and laboratory report.
01598
CITY_21MC100_008873596
NYC-WTC_000416998
OCR can misread numbers and units. Confirm readings against the page image before using them.