NYC-WTC_000415867
Discusses fireproofing condition and asbestos considerations in the Trade Center disaster study.
2 shared non-person entities · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗Glan z and Moss discuss fireproofing study for WTC towers.
NYC-WTC_000415920–000415921OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
THE NEW YORK TIMES, FRIDAY, DECEMBER 14, 2001
terials at W. R. Grace & Co., s&id that the fiber-based fireproofing — espe cially the early asbestos-free ver sions — never had the strength of the cement-like fireproofing that Grace produced. But Mr. Verhalen vigorously de fends the product, known as Blaze- Shield. He said he had no involve ment with Mr. DiBono or his spray ing work. He said his product had been thoroughly tested and approved by Underwriters Laboratories, the independent testing organization. “There is no reason for that prod- , uct in a typical commercial environ ment to deteriorate,’’ he said. Still, a consultant paid by Mr. Ver- halen’s firm during years of litiga tion with the Port Authority has said that there were, in fact, major prob lems over the years with the fire proofing used on the higher floors of the towers. The consultant, Roger G. Morse, said years of inspections had re vealed that whole sections of the original fireproofing had fallen away and other sections had deteriorated. leaving the steel inadequately pro tected. Mr. Morse says Mr. Di Bono’s firm had improperly sprayed the fire proofing onto rusted steel, which would have caused it to slough off. Mr. Morse recently contacted ex- ' perts working on the federally fi nanced investigation of the collapses and turned over hundreds of photo graphs that he said depicted the fail ure to repair the problems with the fireproofing. One expert helping lead the inves tigation, Frederick W. Mowrer, said Mr. Morse’s material had convinced him that the fireproofing had to be scrutinized as a potential contributor to the failures of the buildings.
CITY_21MC100_011834278
NYC-WTC_000415921
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000415867
Discusses fireproofing condition and asbestos considerations in the Trade Center disaster study.
2 shared non-person entities · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000415908
Clipping discussing fireproofing deficiencies in WTC and related repairs.
2 shared non-person entities · 1 shared topics · similarity 0.930
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000415895
Article about fireproofing concerns related to World Trade Center collapse.
1 shared topics · similarity 0.914
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000416159
Report on diesel fuel tank and fire code compliance investigation at World Trade Center.
1 shared non-person entities · 1 shared topics · similarity 0.886
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152327
A financial document from late September 2001 related to water supply operations and emergency response costs.
3 shared non-person entities · 1 shared topics · similarity 0.902
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000142978
News report summarizing findings that twin tower trusses were well-designed and fireproofing was not intended for such impacts.
1 shared topics · similarity 0.892
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000151965
Scientific report comparing air quality data from Ground Zero to other pollution events and noting high particle counts.
1 shared non-person entities · similarity 0.890
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153341
Internal DEP memo forwarding excerpts from EPA-NESHAP revised final document to multiple city agencies for information.
2 shared non-person entities · similarity 0.887
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152026
Internal DEP routing sheet with checkboxes for handling reports, comments, and coordination regarding WTC environmental data.
2 shared non-person entities · similarity 0.887
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152373
Document excerpt showing New York City reservoir levels and related environmental data from the DEP.
3 shared non-person entities · 1 shared topics · similarity 0.885
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000153096
Interagency memo circulating EPA revisions for NESHAP and related programs with request for legal and agency comments.
3 shared non-person entities · similarity 0.885
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000143000
Article discussing landlord responsibilities for reimbursing tenants for apartment cleaning and EPA policies on hallway cleanup requests.
2 shared non-person entities · similarity 0.885
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000415867
Discusses fireproofing condition and asbestos considerations in the Trade Center disaster study.
Similarity score 0.963 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000415908
Clipping discussing fireproofing deficiencies in WTC and related repairs.
Similarity score 0.961 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000415895
Article about fireproofing concerns related to World Trade Center collapse.
Similarity score 0.950 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152327
A financial document from late September 2001 related to water supply operations and emergency response costs.
Similarity score 0.946 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000152327
A financial document from late September 2001 related to water supply operations and emergency response costs.
Similarity score 0.937 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000142978
News report summarizing findings that twin tower trusses were well-designed and fireproofing was not intended for such impacts.
Similarity score 0.936 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000415867
Discusses fireproofing condition and asbestos considerations in the Trade Center disaster study.
Similar indexed content
NYC-WTC_000415908
Clipping discussing fireproofing deficiencies in WTC and related repairs.
Similar indexed content
NYC-WTC_000415895
Article about fireproofing concerns related to World Trade Center collapse.
Similar indexed content
A financial document from late September 2001 related to water supply operations and emergency response costs.
Similar indexed content
NYC-WTC_000142978
News report summarizing findings that twin tower trusses were well-designed and fireproofing was not intended for such impacts.
Similar indexed content