CHAPTER 1—ASBESTOS CONTROL PROGRAM §1-106

(f) Removal of ACM shall be by wet methods in accordance with §1-102. (g) ACM removed shall be placed in a leak-tight container without drop­ ping it. (h) Upon completion of abatement, and prior to tent collapse, the enclosed surfaces shall; (1) be wet cleaned using rags, mops or sponges; and (2) be permitted sufficient time to dry, prior to HEPA vacuuming all substrates; and (3) be lightly encapsulated to lockdown residual asbestos. (i) Upon barrier disturbance, loss of engineering controls, or termination of tent usage, the tent and the enclosed surfaces shall be treated according to subdivision (h) above. (j) The bagged waste shall be wet cleaned or HEPA vacuumed and then transferred outside the tent, double bagged, and appropriately handled prior to disposal. (k) The outer disposable suit (if 2 suits are worn) shall be removed and remain in the tent upon exiting. Following tent disposal and work site cleanup the workers shall immediately proceed to a shower at the work site. The inner disposable suit and respirator shall be removed in the shower after appropri­ ate wetting. The disposable clothing shall be disposed of as asbestos-contain­ ing waste material. The workers shall then fully and vigorously shower with supplied liquid bath soap, shampoo, and clean, diy towels. (1) The negative pressure ventilation equipment shall be used to filter a minimum of 6 volume changes through the tent after completion of abatement but prior to collapse of the tent/barrier. All required air monitoring must be successfully completed before the tent/barrier is collapsed. (m) 'i be tent shall be collapsed inward, enclosing the contaminated cloth­ ing. This contaminated material shall be disposed of in another plastic bag. The HEPA vacuum shall be decontaminated and sealed.

5867 RONY 5-31-98

CITy_21MC100_006242998

NYC-WTC_000411867

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000411867Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Asbestos sampling chain of custody form

NYC-WTC_000233286

Chain of custody form for asbestos samples referencing New York State Department of Labor regulations and sample tracking details.

Similar indexed content

Compare copies and versions →