§1-37 TITLE 15—DEPT. OF ENVIRONMENTAL PROTECTION
(4) Only persons certified by the Department as asbestos investigators
or by New York State Department of Labor as Asbestos Inspectors Certifi
cate may select and collect bulk samples for analysis.
(b) Bulk sample analysis (PLM) shall be performed by laboratories within
the ELAP.
(c) Air Sample Analysis (PCM) shall be performed by laboratories with
the following attributes;
(1) Successful completion by the laboratory’s active analysts of the
NIOSH 582 training course which outlines the NIOSH 7400 method; and
(2) Active analysts with skills in the appropriate methodology and
proficiency in the NIOSH PAT Program for PCM analysis; and
(3) Accreditation in the ELAP.
(d) Air Sample Analysis (TEM) shall be performed by active analysts who
possess skills in TEM analysis and participate in an in-house quality assur
ance program using the National Institute of Standards and Technology
(NIST SRM 1876) or traceable standard.
§1-37 Sampling Equipment Requirements.
(a) Bulk sampling requirements. (1) Bulk samples shall be taken by
whatever method minimizes the potential for fiber release.
(2) Any material which remains exposed as a result of the sampling
procedure shall be sealed.
(b) Area air sampling equipment for Phase Contrast Microscopy (PCM)
shall be utilized in accordance with the equipment and sampling procedures
specified within the NIOSH 7400 Method modified for area sampling.
(c) Area air sampling equipment for Transmission Electron Microscopy
(TEM) shall be utilized in accordance with the sampling procedures specified
within 40 CFR Part 763, Subpart E, Appendix A — Section 11 Mandatory
Transmission Electron Microscopy Method, Subsection B — Sampling.
5762 RCNY 5-31-98
CITY_21MC100_006242962
NYC-WTC_OOO41 1831