Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
yce Analytical'_________ Method 8290 Analysis Results
Tel; 612-607-1700
Far 612- 607-R444
/ Client - ATC ASSOCIATES
Client's Sample ID ATC-0905-M833-DX-3
Lab Sample ID 103841334
Filename F21011B_16
Injected By BAL
Total Amount Extracted 1.00 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 09/05/2002
I CAL Date 10/01/2002 Received 09/10/2002
CCal Filename{s) F21011B_02 & F21011BJ8 Extracted 10/06/2002
Method Blank ID BLANK-2262 Analyzed- 10/12/2002 09:12
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7.8-TCDF 0.0023 0.0022 JA 2,3,7,8-TCDF-13C 2.00 95
Total TCDF 0.0100 0.0020 J 2,3,7,8-TCDD-13C 2.00 87
1,2,3,7,8-PeCDF-13C 2.00 102
2,3,7,8-TCDD ND 0.0027 A , 2,3.4,7,8-PeCDF-13C 2.00 105
Total TCDD 0.0110 0.0020 1,2,3,7,8-PeCDD-13C 2.00 95.
1,2,3,4,7,8-HxCDF’13C 2.00 108
1,2,3,7.8-PeCDF ND 0.0100 1,2,3.6,7,8-HxCDF-13C 2.00 108
2.3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 116
Total PeCDF ND ■ 0.0100. 1.2.3,7,8,9-HxCDF-13C 2.00 114
1,2,3,4,7,8-HxCDD-13C 2.00 93
1,2.3,7,8-PeCDD ND 0.0100 1.2.3,6,7,8-HxCDD-13C 2.00 99
Total PeCDD ND 0.0100 1,2,3,4,6,7,8-HpGDF-13C 2.00 102
1,2.3,4,7,8,9-HpCDF-13G 2.00 103
1,2,3,4,7,8-HxCDF 0.0110 0.0100 J 1,2,3,4,6,7,8-HpCDD-13C 2.00 93
1,2.3.6,7.8-HxCDF ND 0.0100 OCDD-13C 4.00 97
2,3,4,6,7,8-HxCDF 0.0100 0.0100 J
1,2.3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxGDF 0.0320 0.0100 J 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 88
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD 0.0120 0.0100 J
1,2,3,4,6,7.8-HpCDF 0.0400. 0.0100 J Total 2,3,7,8-TCDD
1,2,3.4,7.8.9-HpCDF ND 0.0100 Equivalence: 0.0040 ng/m2
Total HpCDF 0.0720 0.0100 J (Using ITE Factors)
1,2.3,4,6,7,8-HpCDD 0.0730 0.0100
Total HpCDD 0.1400 0.0100
OCDF 0.0880 0.0200 J
OCDD 0.4800 0.0200
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 limes higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * - See Discussion
Report No.....1062384
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,,
without the written consent of Pace Analytical Services, Inc.
CONFIDENTIAL, CITY_2IMCI00_011771488
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000411432