ATC Associates
104 East 25 Street, New York, NY 10010
Phone:(212) 353-8280 Fax:(212) 353-8306
K
Attn: Mr. Bernard Orlan Received: 3/18/02 8:00:00 PM
N.Y.C. Board of Education ATC Group#: 7122
28-11 Queens Plaza North Analysis Date: 3/18/02
Long Island City, NY 11101
Fax: (212)475-4122 Phone: (212) 477-8941
Project: New Stuyvesant H. S., 345 Chambers St., NY , N
Exterior and Interior of Building and Roof
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
Area Non Asbestos # Structures Sensitivity Concentration
Sample yolume Analyzed Asb Typefs) O.Sfi-5 5/t (S/cc) (S/mm^) (S/cc) Notes
1 1920.00 0.0450 .0 NoneDelected 0 0 0.0045 <22.24 <0.0045
7122-1
2 1920.00 0.0450 0 NoneDelected 0 0 0.0045 <22.24 <0.0045
7122 -2
3 1928.00 0.0450 0 NoneDelected 0 0 0.0044 <22.24 <0.0044
7122 -3
' 1928.00 0.0450 0 NoneDelected 0 0 0.0044 <22.24 <0.0044
7122-4
5 1936.00 0.0450 0 NoneDelected 0 0 0.0044 <22.24 <0.0044
7122 -5 ■
S 1936.00 0.0450 0 NoneDelected 0 0 0.0044 <22.24 <0.0044
7122 -6
7 1936.00 0.0450 0 NoneDelected 0 0 0.0044 <22.24 <0.0044
7122 -7
ROMAN PEYSAKHOV MICHAEL A. GORYCKI. Ph.D.
Analyzed by: Approved by:
j Disclaimer. Ttie laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. This lab is only responsible
i for data reported in structures/mmL This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim
i product endorsement by NVLAP or any other agency of the U.S. Government. This reports relates only to the samples reported above. Quality control data (including 95%
confidence limits and laboratory and analysis' accuracy and precision) is available upon request
Accredited for NVLAP PLIWTEM #101187-0, NY State ELAP #10879
Page I of J
CONFIDENTIAL, CITY_21MC100_003388529
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000410645
OCR can misread numbers and units. Confirm readings against the page image before using them.