’.04 East 25th Street New YorK. New York ’,0010 1 www.atc-snviro.com 212.353.8260 212 353.8306 associates INC

October 2001

ALC Environmental 115 W. 30th Street Mew York, MY 10001 Attn; Mr. Joshua Sarett

Re; Report of TEM Analysis

Dear Mr. Sarett:

Eoilowing are tne results of transmission electron microscopy (TEM) analysis of air samples from our Group No. 5613.

Client: Gateway Plaza Mngt. Corp. Project Name: Building 200 at Gateway Plaza - 355 South End Ave. Location; Various Sites Samples received: 10/05/01

These results will confirm and document the data transmitted today to you. The analyses were performed in strict conformance with, the rr.ethodology of the AJiERA Pinal .Rule (OR October 30, 1987; for clearance of abatement sites. As indicated on the atta hed Summary Results sheet, less than 7C asbestos structures per mm- was detected In all of the fifteen samples submittec from r.r.e sits

Results reported as StrucL/cc are a function of air volume collected in the field a.nd are, as such,, not verifiable by this laboratory. This report may be reproduced only in its entirety and not without prior permission of this laboratory. It the post abatement inside samples pass. the response act ton may be considered co have been completed. The analyses were supervised by Dr. Michael A. Gorycki, Director of Electron Microscopy.

We are pleased to note that our TEM lab nas received full accreditation from NVLAP, as is currently required for recognized analysis g£ TEM air samples for AKERA projects, and also approval under the NY State DOH ELA? program. These analyses were performed by ATC d/b/a ATC Associates Inc.

Please contact me regarding any questions relating to these materials .

Very tr-u-y yours,

Michael A. Gorycki , ^h . b . Director of Electron Microscopy

CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 1, J AN. 2013

CITY_DEP_WORBY_CANNATA_SUBP_000000183 NYC-WTC_000409565

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000409565Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000409595

TEM analysis results of air samples from Gateway Plaza Building 200, Oct 2001.

Similar indexed content

Compare copies and versions →