NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 6 pages

Lab report: PCM air sample results, 2002

Machine-extracted title · confidence 35%

Laboratory results for PCM air sample collected 05/31/02, Testwell Laboratories, WTC area.

NYC-WTC_000408786–000408791
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TESTWELL LABORATORIES, INC. Environmental Laboratory NYS SUP # 11142

47 Hudson Street, Ossining, New York 10562 NMAP J 200083-0 AIHA ; ICOHZ

PCM AIR SAMPLE RESULTS Client: Bovis Lend Lease Date Collected: 05/31/02 Date Rec'd (lab); 06/03/02 Project #; MBO-025AB Analysis Date: 06/03/02 Analyst: 4. Soko/ Sample Location Millenium Hilton @ WTC 55 Chruch Street Analytical Method: NIOSH 7400 New York, New York Various Floors Sample Condition Acceptable? YES Field Technician T. Chhetry

Sample Concentration Sample #; Sample Location; 02PCM # Volume Type f/cc

Outside Work Area 43rd Floor inside 403 During 15349 1350 0.0025 Airlock Outside Work Area 43rd Floor 404 During 15350 1350 <0.0020 Freight Elevator Lobby Outside Work Area 42nd Floor Inside 405 During 15351 1350 0.0029 Airlock Outside Work Area 42nd Floor 406 During 15352 1350 0.0022 Freight Elevator Lobby Outside Work Area 41st Floor Inside 407 During 15353 1350 0.0035 Airlock Outside Work Area 41st Floor 408 During 15354 1350 0.0024 Freight Elevator Lobby Outside Work Area Sth Floor Inside 409 During 15355 1350 0.0036 Airlock Outside Work Area Sth Floor Freight 410 During 15356 1350 <0.0020 Elevator Lobby Outside Work Area 40th Floor Inside 411 During 15357 1350 0.0031 Airlock Outside Work Area 40th Floor 412 During 15358 1350 0.0038 Freight Elevator Lobby Outside Work Area 39th Floor Inside 413 During 15359 1350 0.0047 Airlock Outside Work Area 39th Floor 414 During 15360 1350 0.0033 Freight Elevator Lobby * Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is calculated by using the higher value of either die actual concentration or the limit of quantification reported at P(0.05) indicating the 95% confidence level at 2 standard deviations. ** Sample information is provided by the client & presented as stated. **’ Laboratory QC data available upon request. **** The laboratory has no control over air sampling collection. Reports are the confidential property of our clients. This certificate of analysis/reccrt shall net be used by the client to claim product endorsement by the National Voluntary Laboratory Approval Program (NVLAF) or any agency of the United States Government. This certificate of analysis/report shall not be repredueso except in full, without the written approval of Testweil Laboratories, Inc.

Deborah McCari - Laborator/ Director

Page 1 of 1

CITY_21MC100_011962991

NYC-WTC_000408788

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000408788Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →