III ’ I inv. 11.| Lh E.nvironmental Labori .y 111||0 47 Hudson Street. Ossining, New York 10562 CONF!DE^mF= ""'AIHA# 100147

CERTIFICATE OF LABORATORY ANALYSIS FOR ASBESTOS CONTENT CLIENT; Eiovis Land Lease - LMB Project No: MBO-025AB Collected By: Boris Feldman Date Sampled: 09/30/01 Date Analyzed: 10/03/01 PROJECT; Millenium Hilton Hotel PLM Analyst; V. Binchkauskas Church Street TEM Analyst; N/A New York, New York

I NUMBER: | LAB ID # | DESCRIPTION iMATRIXl RESULTS (%) J Floor 6-At Storage Tank-Dust on Chrysotile = 0.57% Cellulose = 60% 133 01PLM#8164 Friable Floor Fiberglass = 20% Non-Fibrous = 19.43%

Cellulose=50% Other= 3% 134 01PLM#8165 Floor 6-Chiller Room-Dust on Floor Friable Fiberglass = 20% Non-Fibrous = 27%

Floor 4-Board Room-Debris on Chrysotile = .80% Cellulose = 10% 135 01PLM#8166 Friable Floor and Furniture Fiberglass = 55% Non-Fibrous = 32.59%

Floor 4-Soho-Debris on Floor and Chrysotile = .52% Cellulose = 10% 136 01PLM#8167 Friable Furniture Fiberglass = 50% Non-Fibrous = 39.48%

Floor 4-Chelsea-Debris on Floor Cellulose = 10% Fiberglass = 55% 137 01PLM#8168 Friable and Furniture Non-Fibrous = 35%

Chrysotile ? 1.08% Cellulose = 36% 138 01PLM#8169 Floor 56-MER-Debris on Floor Friable Fiberglass = 35% Non-Fibrous = 28.92%

139 01PLM# 8170 Floor 56-MER-Debris on Floor Friable Not Analyzed-Homogeneous Area

140 01PLM#8171 Floor 56-MER-Debris on Floor Friable Not Analyzed-Homogeneous Area

Floor 54-Stair A-Dust on Intake Air Cellulose = 75% Fiberglass = Trace 141 01PLM# 8172 Friable Louver Non-Fibrous = 25%

Floor 47-Stair B-Dust on Intake Air Cellulose = 75% Other = 5% 142 01PLM#8173 Friable Louver Fiberglass = T race Non-Fibrous = 20%

(1) Sample Ir formation provided on chain of custody assumed correct (2) Samples homogenized by mortar & pestle prior to analysis. (3) Results only pertain to those items tested. (4) The laboratory has non control over sample collection. This certificate of analysis shall not be reproduced expect in full, without the written approval of Testwell Laboratories, Inc.

o nvLap* AIHA ; Deborah McCart-Laboralones Oiraetor (as it pertains to bulk sample analysis under certification 200083-0) This report and use of above logos must not be used to claim endorsement by AIHA, NVLAP, NIST or any other Federal or State regulatory agencies

CONFIDENTIAL, SUBJECTTO PROTECTIVE ORDER NO. 1, JAN. 2013

CITY_DEP_WORBY_CANNATA_SUBP_000000644

NYC-WTC_000408718

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000408718Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →