NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 73 pages

Debris transfer, Staten Island plan draft, Oct 2001

Machine-extracted title · confidence 28%

Draft environmental health and safety plan for debris transfer and landfill operations, Oct 2001.

NYC-WTC_000408541–000408613
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Staten Island Landfill Debris Disposal Operation Health and Safety Program

number will be posted at the job site for use in the event of an emergency. No smoking is permittedwithin 50 feet radius of gas extraction wellheads.

4.2.3 Illumination

Illumination levels for various work processes have been specified in EM 358-1-1, Section 07.A.01 and are shown below:

Means of egress- Means of egress shall be illuminated, with emergency and non-emergency lighting, to provide a minimum of 11 lux (lx) (1 footcandle (Im/ft)), measured at the floor. Additionally, illumination shall be arranged so that the failure of any single lighting unit, including the burning out of an electric bulb, will not leave any area in total darkness. MINIMUM LIGHTING REQUIREMENTS Facility or function Illuminance - lx (Im/ft) 2 Accessways - General indoor 55 (5) - General outdoor 33 (3) - exitways, walkways, ladders, stairs 110(10) Administrative areas (offices, drafting and meeting rooms, etc.) 540 (50) Chemical laboratories 540 (50) Construction areas - General indoor 55 (5) - General outdoor 33 (3) - Tunnels and general underground 55 (5) Work areas (minimum 110 lux required at tunnel and shaft heading during drilling, mucking, and scaling) Conveyor routes 110(10) Docks and loading platforms 33 (3) Elevators, freight and passenger 215(20) First aid stations and infirmaries 325 (30) Maintenance/operating areas/shops

27

NYC-WTC_000408570

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000408570Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000165900 · Box 7DDC

Document page containing contact details for Con Edison and JWC Environmental Health & Safety personnel.

Similar indexed content

Compare copies and versions →