Vol. 51 / No. 21 MMWR 455
wsMiHiMCMBieKbiaeaifiafaKSBtBetiBKxaeaBn e»ea awansBUsssaw i3K3ean Ricsi«a»jew'4
of co ranged from 0.2 to 242.0 ppm; the highest finding The absence of exposure to respirable crystalline silica,
(in a 32'/2-minute PBZ sample from a saw operator) exceeded despite its presence in the bulk samples, indicates either that
the NIOSH limit of 200 ppm and would have exceeded the the crystalline silica in the dust at the sire consisted of larger,
PEL of 50 ppm (8-hour TWA) had it been sustained for nonrespirable particles or that work activities were not caus
2 hours {1,2). CO concentrations of 4l ppm and 45 ppm in ing the dust to become airborne. In the absence of effective
PBZ samples from torch cutters and 40 ppm in a GA sample dust-control measures, the former explanation seems more
near a saw operator, with sampling durations of*/?, 5, and 214 likely. Although the air sampling indicated the presence of
hours, respectively, would have exceeded the REL of 35 ppm respirable airborne particulate, this material was apparently
had they represented full-shift exposures {1,2). not crystalline silica. One torch cutter had cadmium overex
Hydrogen sulfide was present in seven of 10 samples, one posure, and excess CO was associated with workers using oxy
or more inorganic acids in all 27 samples, mercury in five of acetylene torches and gasoline-powered saws. To reduce CO
16 samples, and one or more VOCs in 14 of 76 samples; all exposure, NIOSH recommended replacing gasoline-powered
concentrations w'ere below applicable NIOSH and OSHA saws with rechargeable, battery-powered saws.
exposure limits except for two benzene concentrations (0.4 At the time of the NIOSH sampling, the ambient air did
mg/m^ and 0.5 mg/m^) that exceeded the REL of 0.3 mg/m^ not appear to be contaminated with toxic subsiance,s from
{!). Both were in GA samples from a smoke plume and did the buildings or their contents or with combustion products
not represent any specific worker’s exposure. The highest con to an extent that posed an occupational health hazard. How
centration of elemental carbon (an indicator of diesel exhaust) ever, the presence of hazards related ro specific work activities
was 0.023 mg/m^. Neither NIOSH nor OSHA has a at the WTC disaster site underscores the importance of
numerical exposure limit for diesel exhaust, but the Ameri assessing suspected occupational exposures. In response to the
can Conference of Governmental Hygienists has proposed a WTC disaster, NIOSH has issued guidelines for addressing a
limit of 0.2 mg/m^ (measured as elemental carbon) (4). No variety of occupational safety and health hazards at disaster
Freon -22 was detected in any of five samples. Small amounts sites (5).
of various PAHs were present in all 12 samples, but not at
concentrations that exceeded individually or collectively Acknowledgments
any applicable NIOSH or OSHA exposure limit. Thi.s report is based on data contributed by: New York City School
Reported by: K MclCinney, MPA, Neiv York City Dept of^Pfealth: Construction Authority. Data Chern Labor.rtcrics, Salt Lake City,
S Benson, New York City Office ofEmergency Management; A Lempert, Utah. B Bernard, MD, D Booher, G Burr, E Esswein, MSPH,
New York City School Construction Authority. M Singal, MD, R Hall, .MS, J Harney, MS, D Hewett, MS, B King, MPH,
Cincinnati, Ohio. K Wallingforel, MS, E Snyder, MS, Div of S Lenhart, MSPH, B Lushniak, MD, R McClccry, MSPH,
Survetllartce, I la car2 Evaluations and Eield Studies, Natio/tal Institute K Martinez, MSEE, D Mattorano, MS, A Weber, MS, Div of
for Occupational Safety and Health, CDC. Surveillance, Hazard Evaluations, and Field Studies; K Linch, MS,
P Middendorf, PhD, Div of Respiratory Disease Studic.s; S Earnest,
Editorial Note: In addition to the physical hazards associ
PhD, AEcht, MPH, J Fcrnback, A Grote, CNcumeistcr, E Kennedy.
ated with work at the WTC site, hazardous exposures co toxic PhD, T Zimmer, PhD, Div of Applied Research Technology,
dusts and gases were suspected initially. Asbestos exposure, in National Institute for Occupational Safety and Flealth, CDC.
particular, was an occupational and community health con
References
cern. The findings of this survey documented no occupational 1. National Institute for Occupational Safety and Health. NIOSH pocket
exposure to asbestos, at least after September 18, in excess of guide to chemical hazards. Cincinnati, Ohio: U.S. Department of Health
NIOSH or OSHA occupational exposure limits. The seven and Human Services, CDC, National Institute for Ciccupational Safety
and Health, 1997 (DHHS publication no. 97-140),
air samples that had fiber concentrations (determined by
2. Occupational Safety and Health Administration. Toxic and hazardou.s
PCM) higher than the REL for asbestos probably would have substances, 29 C.F.R. 1910 Subpart Z. U.S. Department of Labor,
had asbestos concentrations <0.1 f/cc if analyzed byTEM. In Occupational Safety and Health Administration. Available at http://
many other samples, asbestos concentrations determined by www.osha-51c.gov/OsliStd_toc/OS14A_Std_toc_1910_SLJBI ’ART_Z.html.
3. National Institute for Occupational Safer)’ and Health. NIOSFl m.anua!
TEM tended to be lower than those determined by PCM. of analytical methods, 4th cd. Cincinnati, Ohio: U..S. Deparunent of
The NIOSH asbestos sampling did not provide data about Health and Human Services, CDC, National Institute for Occupational
occupational exposures before Sep tember 18 and was designed Safciyatid Health, 1994 (DHHS publication no. 92-113).
4. American Conference of Government Industrial Hygienists, Threshold
to assess occupational exposures, not community exposures, limit values for chemical substances and physical agents & biological
which probably were lower. exposure indices. Cincinnati, Ohio: American Conference of Govern
mental Industrial Hygienists, 2001.
Sii»3«ass»Ka^
CITY_21MC1OO_OO6646425
NYC-WTC_000407249
OCR can misread numbers and units. Confirm readings against the page image before using them.