Chain of custody form, Reading, PA

Machine-extracted title · confidence 28%

Chain of custody record for PSC Analytical Services in Reading, PA.

NYC-WTC_000407130–000407133
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

INDUSTRIAL HYGIENE ENVIRONMENTAL TESTING PSC •EPAAWLAP 101262-0 •NY DOHMELAC 10903 •NJOEP PAC20 •AIHA ACCREDITATION NO. 100439 • PA DEP 09-353 •CT DPHPH.0238 •NC OENR S9d Analytical Results for ATC Associates WorkOrder: R02050497 Client Reference: 19125-0290

Analyte Concentration Limit of Test Date Analyzed Detection .Method /Analyst (“&) : (mg/m') : (ppm) (UE)

Client ID; ATC-05I0-MS94-M5 Lab ID; -OSA Date Sampled; 5/10/02 Matrix: Filter Air Vol.(L): NA Aluminum <1.00 1 N7300 MCE 05/22/2002 AJB Cadmium <0.200 0.2 N730O MCE 05/22/2002 AJB Chromium 0.754 0.2 N73OO MCE 05/22/2002 A-'B Cobalt <0.100 0.1 N73Q0 MCE 05/22/2002 AJB Copper <0.200 0.2 N730O MCE 05/22/2002 AJB Iron <2.00 2 N7300 MCE 05/22/2002 AJB Lead <0.300 0.3 N7300 MCE 05/22/2002 AJB Magnesium <1.30 1.3 N73OO MCE 06/22/2002 AJB Manganese <0.300 0.3 N7300 MCE 05/22/2002 AJB Molybdenum <1.00 1 N7300 MCE 05/22/2002 AJB Nickel <0.200 0.2 N7300 MCE 05/22/2002 AJB Zinc <0.500 0.5 N7300 MCE 05/22/2002 AJB

Client ID: ATC-O5IO-M894-Me Lab ID: -06A Date Sampled: 5/10/02 Matrix: Filter AirVol.(L):NA Aluminum <1.00 1 N7300 MCE 05/22/2002 AJB Cadmium <0.200 0.2 N7300 MCE 05/22/2002 AJB Chromium 0.423 0.2 N7300 MCE 05/22/2002 AJB Cobalt <0.100 0.1 N7300 MCE 05/22/2002 AJB Copper <0.200 0.2 N7300 MCE 05/22/2002 AJB Iron <2.00 2 N73Q0 MCE 05/22/2002 AJB Lead <0.300 0.3 N7300 MCE 05/22/2002 AjB Magnesium <1.30 1.3 N7300 MCE 05/22/2002 AJB Manganese <0.300 0.3 N7300 MCE 05/22/2002 AJB Molybdenum <1.00 1 N7300 MCE 05/22/2002 AJB Nickel <0.200 02 N73O0 MCE 05/22/2002 AJB Zinc <0 500 0.5 N7300 MCE 05/22'2002 AJB

(a) Analysis indicates possible breakthrough; bock section result is greater than 0% of the front section result.

General Notes: <: Less than the indicated limit of detection (LOD). Information not available or not applicable. Back sections were checked and showed no significant breakthrough.

Page 3 of 3

CITY_21MC1OO_OO29O3367

NYC-WTC_000407133

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000407133Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →