Mr. Bernard P. Orlan April 23, 2002 Indoor Air Quality Measurements Page 3 Stuyvesant High School (M477)_______________ ATC Project No. 15-19125-0246 Real-Time Environmental Measurements

ATC collected one hundred and twenty (120) sets of real-time environmental measurements consisting of one hundred and eighteen (118) in the school building and two (2) outdoors. All ten floors of the school were surveyed. These results are described below.

Field data sheets are found in Attachment 1. Readings began at 7:50 A.M. and concluded after 1:10 P.M.

Temperature

Indoor dry bulb temperature measurements ranged from 65.6 °F to 74.5 °F. Fifty (50) of the measurements for indoor temperature were below and sixty-eight (68) measurements were within the range of 73 to 79°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during summer conditions. The outdoor temperature range was 59 to 59.6 °F.

Relative Humidity

The relative humidity indoors ranged from 32 percent to 45.5 percent. All of the indoor measurements for relative humidity were within the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity levels were 47.8 and 53.9 percent.

Carbon Dioxide Concentration

Carbon dioxide concentrations indoors ranged from 424 ppm to 1244 ppm. Twenty-three (23) measurements were above the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The outdoor (background) CO2 concentrations were 416 and 451 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1151 ppm (background level + 700 ppm). The highest concentration (1244 ppm) was measured in room 1007 at 12:50 PM with 30 occupants. Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO2 indoors is occupant respiration.

Carbon Monoxide Concentration

Carbon monoxide concentrations indoors ranged from 0 ppm to 1 ppm. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentrations ranged from 0 ppm to 1 ppm.

Respirable Particulates (PM2_5)

Respirable particulate concentrations* indoors ranged between 2 pg/m^ to 18 pg/m^ with an average of approximately 12 pg/m^. All of the indoor measurements for PM2.5 were below the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter and the USEPA recommendation of 40 pg/m^ for sensitive individuals and children. The outdoor respirable particulate concentrations were 14 and 45 ugm-.

CITY_21MC100_002902808

NYC-WTC_000406606

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000406606Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000336148

May 2002 IAQ measurements at Stuyvesant High School for BOE.

Similar indexed content

NYC-WTC_000229474

Report from ATC Associates detailing indoor air quality measurements collected at Stuyvesant High School on April 23, 2002.

Similar indexed content

NYC-WTC_000395300

ATC letter reporting indoor air quality assessment at Stuyvesant High School, June 2002.

Similar indexed content

Compare copies and versions →