NYC 9/11 Public Portal Document Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 mAnalyticar Minneapolis, MN 55414 Phone: 612.607.1700 mm.pacelabs.com Fax: 612.607.6444 TABLE 3. Exact Son Masses Monitored for the Determination of PCDDs, PCDFs, and PGDEs

Accurate Mass TSieoretical Ratio Compound Mass H Mass 2 Mass 1/Mass 2

Tetra-CDDs 319.8965 321.8936 0.77 Tetra-CDFs 303.9016 305.8987 0.77 Hexa-CDPEs 375.8364

Penta-CDDs 355.8546 357.8517 1.54 Penta-CDFs 339.8597 341.8567 1.54 Hepta-CDPEs 409.7974

Hexa-CDDs 389.8156 391.8127 1.23 Hexa-CDFs 373.8207 375.8178 1.23 Octa-CDPEs 445.7555

Hepta-CDDs 423.7766 425.7737 1.03 Hepta-CDFs 407.7817 409.7788 1.03 Nona-CDPEs 479.7165

Octa-CDD 457.7377 459.7347 0.88 Octa-CDF 441.7428 443.7398 0.88 Deca-CDPE 513.6775

CDDs = Chlorinated Dibenzo-p-dioxins CDFs = Chlorinated Dibenzofurans CDPEs = Chlorinated Diphenylethers

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

CITY_21MC100_002898121

NYC-WTC_000402651

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000402651Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000228425

Comprehensive laboratory report containing results for environmental testing conducted by Pace Analytical Services for a New York City Board of Education project.

Similar indexed content

PCDD/PCDF lab analysis results, Jan 2002

NYC-WTC_000226877

Pace Analytical laboratory report detailing polychlorinated dibenzo-p-dioxin and dibenzofuran levels in samples from a NYC school.

Similar indexed content

Compare copies and versions →