Mr. Bernard P. Orlan January 28, 2002
Air Sampling for Metals Page 2
Stuwesant High School ATCProiectNoaM9121:0246
Results
The levels of airborne metals did not exceed the limits of detection in any of the samples except
for chromium as follows:
Sample number ATC-0117-STY- Ml (obtained from 1“ floor main lobby) was reported to be
0.00543 mg/m^; Blank corrected 0.000235 mg/m^.
Sample number'ATC-0117-STY- M2 (obtained from the 2“^ floor lobby bridge entrance) was
reported to be 0.00473 mg/m^; Blank corrected 0.000164 mg/m\
Sample number ATC-0117-STY- M3 (obtained from the Roof air intake) was reported to be
0.00638 mg/m^ Blank corrected 0.000329
Sample number ATC-0117-STY- M4 (blank) was reported to be 0.296 micrograms per filter.
The result of the blank indicates that chromium is a contaminant on the field blank.
All chromium levels were below the EPA level of 0.6 ug/m\
ATC appreciates the opportunity to provide this indoor air quality service to the BOE. Please call
me at (212) 353-8280 extension 212 if you have any questions.