Mr. Bernard P. Orlan February 14, 2002
Wipe Sampling for PCBs Page 2
Stuyvesant High School (M477~) ATCProiectNo. 15-19125-0246
The areas sampled were:
• 1st floor Main Lobby;
• 2^^ floor Bridge Entrance Lobby;
• Roof.
Each sample was analyzed for seven PCB compounds with differing percentages of chlorine.
The PCB results of all samples were below the reporting limits (2.0 micrograms/sample). The
same results were reported for the blank.
Currently, the Environmental Protection Agency spill clean-up standard for PCBs on non-porous
surfaces is 10 micrograms per 100 square centimeters or less (<10 ug/lOOcm^) as stated in 40
CFR761.
It is our pleasure to provide these indoor environmental services to the New York City Board of
Education. If you have any questions about this report, please call (212) 353-8280, extension
212 or 261.
t
Sincerely,
A TC ASSOCIA TES INC.
James R. Cohn, CIH, CSP
Regional Manager
Industrial Hygiene Division
Attachment