NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 23 pages

Lab report, Pace Analytical, 23 pages

Machine-extracted title · confidence 27%

Pace Analytical report with 23 pages; chemistry/NELAC standards; project ID partially visible.

NYC-WTC_000400775–000400797
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

“i:

; f (■.-■I-,.-''

si Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 '■37 we Analytical’S Minneapolis, Ml\l 55414 Phone: 612.607.1700 www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612.607:6444 A ? PROJECT: PCDD/PCDF ANALYSES DATE: January 31, 2002

, PAGE: 4 REPORT NO: 02-1053012 3 -• ' 433 , PCDD/PCDF Quantification and Calculations :S' , -- The PCDD/PQDF Isomers were quantified by comparison of their responses to the responses of the . labeled intenhl^ standards. Relative response factors were calculated from analyses of standard mixtures^cbntaining representatives of each of the PCDD/PCDF congener classes at five concentration levels, and each of the internal standards at one concentration level, as shown in Xa^ie 4, The PCDD/PCDF response factors were calculated'by comparing the sum of. the ^fresponses from the two ion masses monitored for each chlorine congener class to the sum of. the 3 ' responses from the two ion masses of the corresponding isotopically labeled internal standard. The Q formula for the response factor calculation is: 'a An X Qis '4 Rf = Ais X Qn

where: 3 Rf = Response factor ■■f An = Sum of integrated areas for native isomer >4 Qis = Quantity of labeled internal standard Ais = Sum of integrated areas for labeled internal standard r-Ti Qn = Quantity of native isomer « . 2 . The levels of PCDD/PCDF in each sample were quantified using the following equation:

An X Qis ' C = Ais X W X Rf where:

Q C = Concentration of target isomer or congener class Q An = Sum of integrated areas for the target isomer or congener class Qis = Quantity of labeled internal standard added to the sample * ; . Ais = Sum of integrated areas for the labeled internal standard J .W = Sample amount Rf = Response factor

a REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc. -3-

3 CITY_21MC100_002896333

NYC-WTC_000400779

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000400779Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000400723

PACE lab report; 30 pages, NELAC standards, project 19125-0246.

Similar indexed content

NYC-WTC_000400801

Pace Analytical lab report, 24 pages, Project [name], ATC 19125-0246; lab analysis details.

Similar indexed content

PCDD/PCDF lab analysis results, Jan 2002

NYC-WTC_000226877

Pace Analytical laboratory report detailing polychlorinated dibenzo-p-dioxin and dibenzofuran levels in samples from a NYC school.

Similar indexed content

Compare copies and versions →