Mr. Bernard P. Orlan April 25, 2002
Air Sampling for Silica Page 2
P. S. 89 (Manhattan) ATC Project No. 15-19125-0297
Both samples contained 0.0108 milligrams of silica per cubic meter of air (mgm''). The amount
of quartz in these samples was 22%, therefore the PEL for this dust would be;
lOmg/m^ 0.417 mg/m^
22 + 2
The silica concentration in this sample was 2.6% of the calculated PEL.
The OSHA PEL is the only regulatory standard for silica exposure, however it is intended for
occupational exposure in settings such as foundries, sandblasting, rock drilling, etc. The EPA
does not have an ambient-air quality standard for silica.
ATC appreciates the opportunity to provide this indoor air quality consultative service to the
BOE. Please call me at (212) 353-8280 extension 212 if you have any questions.
Sincerely,
ATC Associates, Inc.
James R. Cohn, CIH, CSP
Regional Manager
Industrial Hygiene Division