Analytical results for ATC, Mar 2002

Machine-extracted title · confidence 50%

ATC work order RO2030382 analytical results for metals.

NYC-WTC_000399709–000399711
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mar 15 02 04:20p PSC Rnalytical Services 6103219BB7 p. B

INDUSTRIAL HYGIENE ENVIRONMENTAL TESTING • EPA/NVtAP 101262-0 • NY DOH/NEtAC 10903 ■NJ DEP PA020 • AIHAACCREDITATION NO. 100439 • PA DEP 0E-3S3 • CT DPH PH-C238 •NC DENR5B9

ANALYTICAL SERVICES Analytical Results for ATC Associates WorkOrder: R02030382 Client Reference: 19125-0297

Analyte Concentration Limit of Test Date Analyzed Detection Method /Analyst (ug) (mg/m’) • (ppm) (us) Client ID: M5 ATC-0307-S9M X' !' Lab ID: -OSA Date Sampled: 3/7/02 Matrix: Filter Air Vol.(L): NA Aluminum 1.10 1 N73O0 MCE 03/14/2002 TH Cadmium <0.200 0.2 N730O MCE 03/14/2002 TH :iiromlum 0.294 0.2 N7300 MCE 03/14/2002 TH Cobalt <0.100 0.1 N7300 MCE 03/14/2002 TH Copper <0.200 0.2 N73O0 MCE 03/14/2002 TH Iron <2.00 2 N73O0 MCE 03/14/2002 TH Magnesium <1.30 1.3 N7300 MCE 03/14/2002 TH Manganese <0.300 0.3 N73O0 MCE 03/14/2002 TH Molybdenum <1.00 1 N73O0 MCE 03/14/2002 TH Nickel <0.200 0.2 N73O0 MCE 03/14/2002 TH Zinc <0.500 0.5 N73O0 MCE 03/14/2002 TH

(a) Analysis indicates possible breakthrough; back section result is greater than 0% of the front section result.

General Notes: <: Less than the indicated limit of detection (LOD). —; Information not available or not applicable. Back sections were checked and showed no significant breakthrough.

Page 3 of3

CITY_21MC100_002922204

NYC-WTC_000399711

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000399711Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000297527

Analytical results for ATC work order R02020649, metals in air analysis.

Similar indexed content

Compare copies and versions →