Mr. Bernard P. Orlan January 11, 2002 Real-Time Air Monitoring Page 3 ■ P.S. 234 /Manhattan) ATC Project No. 15-19125-0279

REAL-TIME SAMPLING RESULTS

ATC collected real-time environmental measurements in eight locations three times on December 8, 9 and 10 and twice on December 12. Four sets of readings were collected outdoors and four sets were collected indoors. These measurements were made while the building was unoccupied except for ATC and custodial persoiuiel. As such, the results may not reflect conditions when school is in session and the building is fully occupied by students and staff. lAQ field report forms are provided in the attachment.

The sampling locations, specified by the parents association consultant, were: Cafeteria, Room 118, 2*^^ floor hallway. Room 315, Outdoors by main entrance. Outdoors in front courtyard. Outdoors in back playground. Roof by the air intake.

Basic Parameters Temperature, relative humidity, CO2 and CO readings were within acceptable ranges on all four days considering that that building was not occupied. CO2 levels, which would be expected to rise overtime in an occupied building, were virtually indistinguishable from outdoor levels in this case. Relative humidity and CO were also the same, indoors and outdoors. All of the indoor measurements were collected when the building was unoccupied except for ATC and custodial personnel and do not indicate conditions when students, faculty and staff are present. The temperature and relative humidity levels were below guideline ranges (Table 1), other parameters were acceptable. There were no appreciable changes any of the values over the measurement period. Temperature and CO2 levels would be expected to rise when the building is fully occupied.

Respirable Particulates fPMy s) Table,2,summarizes the PM2.5 data for each day. Indoor levels consistently reflected outdoor levels. TABLE 2 PM2.5 LEVELS MICROGRAMS PER CUBIC METER (ug/m3)

. DATE LOCATION AVERAGE HIGII LOW ’ "f............... . ■ < Indoors 27 68 13 Dec. 8 Outdoors 26 35 20

Indoors 22 27 7 Dec. 9 Outdoors 23 27 17

Indoors 36 55 18 Dec. 10 Outdoors 51 61 45 Indoors 35 44 23 Dec. 12 Outdoors 52 66 46

CITY_2IMCl0 0_0 00490264 NYC-WTC_000396220

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000396220Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →