NYC-WTC_000373506
Real-time IAQ monitoring report for P.S. 234M in December 2001 and January 2002.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗ATC monitoring report detailing real-time IAQ measurements at PS 234 following BOE request, Dec 8–12, 2001.
NYC-WTC_000396218–000396222OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan January 11, 2002 Real-Time Air Monitoring Page 3 ■ P.S. 234 /Manhattan) ATC Project No. 15-19125-0279
REAL-TIME SAMPLING RESULTS
ATC collected real-time environmental measurements in eight locations three times on December 8, 9 and 10 and twice on December 12. Four sets of readings were collected outdoors and four sets were collected indoors. These measurements were made while the building was unoccupied except for ATC and custodial persoiuiel. As such, the results may not reflect conditions when school is in session and the building is fully occupied by students and staff. lAQ field report forms are provided in the attachment.
The sampling locations, specified by the parents association consultant, were: Cafeteria, Room 118, 2*^^ floor hallway. Room 315, Outdoors by main entrance. Outdoors in front courtyard. Outdoors in back playground. Roof by the air intake.
Basic Parameters Temperature, relative humidity, CO2 and CO readings were within acceptable ranges on all four days considering that that building was not occupied. CO2 levels, which would be expected to rise overtime in an occupied building, were virtually indistinguishable from outdoor levels in this case. Relative humidity and CO were also the same, indoors and outdoors. All of the indoor measurements were collected when the building was unoccupied except for ATC and custodial personnel and do not indicate conditions when students, faculty and staff are present. The temperature and relative humidity levels were below guideline ranges (Table 1), other parameters were acceptable. There were no appreciable changes any of the values over the measurement period. Temperature and CO2 levels would be expected to rise when the building is fully occupied.
Respirable Particulates fPMy s) Table,2,summarizes the PM2.5 data for each day. Indoor levels consistently reflected outdoor levels. TABLE 2 PM2.5 LEVELS MICROGRAMS PER CUBIC METER (ug/m3)
. DATE LOCATION AVERAGE HIGII LOW ’ "f............... . ■ < Indoors 27 68 13 Dec. 8 Outdoors 26 35 20
Indoors 22 27 7 Dec. 9 Outdoors 23 27 17
Indoors 36 55 18 Dec. 10 Outdoors 51 61 45 Indoors 35 44 23 Dec. 12 Outdoors 52 66 46
CITY_2IMCl0 0_0 00490264 NYC-WTC_000396220
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000373506
Real-time IAQ monitoring report for P.S. 234M in December 2001 and January 2002.
15 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000177887
Letter and report detailing real-time indoor air quality monitoring conducted at the school in December.
15 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208064
ATC Associates report on real-time air monitoring conducted at P.S. 89M in December 2001 to assess environmental conditions.
13 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383963
ATC reports real-time air monitoring results conducted December 15–16, 2001 at the referenced school.
13 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400531
Real-time IAQ report for PS 89M covering Dec 15-16, 2001, by ATC Associates.
13 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000325955
Memo presenting real-time air monitoring results for PS 89M, December 2001.
13 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000226869
Cover letter from ATC Associates to the Board of Education submitting indoor air quality measurement results for PS89M.
11 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383986
ATC IAQ measurements collected January 16, 2002 at the referenced school.
11 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000371828
ATC indoor air quality report for PS 234M; measurements collected in April 2002.
10 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000373529
Indoor air quality report for P.S. 234M, January 22, 2002.
11 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400563
IAQ report for January 18, 2002, at PS 89M with multiple measurements.
11 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400554
IAQ report detailing measurements collected January 15, 2002 at PS 89M.
11 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000373506
Real-time IAQ monitoring report for P.S. 234M in December 2001 and January 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000177887
Letter and report detailing real-time indoor air quality monitoring conducted at the school in December.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182875
Report of indoor air quality measurements collected at PS 234M on February 7, 2002, as part of a program to maintain acceptable air quality.
Similarity score 0.974 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000208064
ATC Associates report on real-time air monitoring conducted at P.S. 89M in December 2001 to assess environmental conditions.
Similarity score 0.974 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000187685
Cover letter from ATC Associates submitting an indoor air quality assessment report for PS150M collected on March 13, 2002.
Similarity score 0.974 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000374688
IAQ measurements at P.S. 150M prior to re-occupancy, Apr 2002.
Similarity score 0.974 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000373506
Real-time IAQ monitoring report for P.S. 234M in December 2001 and January 2002.
Similar indexed content
NYC-WTC_000177887
Letter and report detailing real-time indoor air quality monitoring conducted at the school in December.
Similar indexed content
NYC-WTC_000208064
ATC Associates report on real-time air monitoring conducted at P.S. 89M in December 2001 to assess environmental conditions.
Similar indexed content
NYC-WTC_000383963
ATC reports real-time air monitoring results conducted December 15–16, 2001 at the referenced school.
Similar indexed content
NYC-WTC_000400531
Real-time IAQ report for PS 89M covering Dec 15-16, 2001, by ATC Associates.
Similar indexed content