NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Wipe sample dioxin report, PS 234M, 2001

Machine-extracted title · confidence 58%

ATC report of wipe samples for dioxins at PS 234M, December 2001.

NYC-WTC_000395839–000395841
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan December 28, 2001 Wipe. Sampling for Dioxins Page 2 P. S. 234 (Manhattan) ATC Project No. 15-19125-0279

Combustion of PCB-containing oils, such as during an electrical transformer fire, is known to produce dioxins. Burning of some plastics may also produce dioxins. Dioxins are toxic and are considered to be carcinogenic.

The Environmental Protection Agency has a screening level for dioxins in air of 0.16 nanograms per cubic meter (0.16 ng/m^). A nanogram is a thousandth of a microgram (1 X 10'9 gram). The Occupational Safety and Health Administration (OSHA) has not established a Permissible Exposure Limit (PEL) for dioxin in air or on surfaces.

The New York State Department of Environmental Conservation (NYSDEC) has set 0.0006 parts per million (ppm) as the allowable concentration of dioxin in soil.

WIPE SAMPLING RESULTS

ATC submitted ten wipe samples for PCDDs/PCDFs (plus one blank) to Pace for analysis. A copy of the laboratory report,is provided in Attachment 1. Samples were taken from areas specified by the parents association consultant. The sample areas ranged from 0.64 to -i .85 square meters (m^). The sample locations and the areas are shown in the table as well as the results

Each sample was analyzed for sixteen (16) PCDD/PCDF isomers. The results for each isomer were then converted to 2, 3, 7, 8 -tetrachloro-dibenzo-p-dioxin (2, 3, 7, 8-TCDD) equivalents by multiplying by an established equivalency factor (See Attachment). This provides a single value (in nanograms) for the analytical results for each sample.

DIOXIN WIPE SAMPLE RESULTS (2,3, 7, 8 TCDD EQUIVALENTS)

Windowsill - Cafeteria/DXl I 0.1041 Kitchen Serving Windowsill/DX2 1.34 0.037 Roomll6-Table/pX3 0.00074 Room 120 - WindowsUl/DX4 0.98 0.017 Room 211-Table/DX5 0.95 0.00054 Library-Table/DX6 1.00 0.00018 Library - Top of Bookcase/DX? TUT .0.00049 Room 305 - - Bookcase//DX8 ITS? 0.00032 Room 316-Table/DX9 0.9 0.00028 Gym stairway floor by door 106/ TIT 0.00 DXIO Blank/DXll 0.000034

CITY_21MC100_002890392

NYC-WTC_000395840

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000395840Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →