NYC 9/11 Public Portal Document
■Attn: Mr. Bernard Orlan Received: 4/17/02 8:00:00 PM
N.Y.C. Board of Education ATC Group#: 7444
28-11 Queens Plaza North Analysis Date: 4/17/02
Long Island City, NY 11101
Fa.x: (212) 475-4122 Phone: (212) 477-8941
Project: PS 89M 201 Warren Street, New York, NY
Playground, Roof All Floors Hallway
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
Area Non Asbestos rl Structures Sensitivity Concentration
Sample l^oliime Analyzed Asb Type(s) O.S/i-S 5fl (S/cc) (S/min^) (S/cc) ISotes
OS 1840.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047
7444 -S
09 1840.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047
7444 -9
10 1840.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047
7444 -10
11 1840.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047
7444 -1/
12 1805.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047
7444 -12
13 1805.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047
7444 -/3
14 1805.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047
7444 -14
15 1805.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047
7444 -15
16 1805.00 0.0450 0 None Detected 0 0 0.0047 <22.24 <0.0047
7444 -16
ROMAN PEYSAKHOV MICHAEL A. CORYCKI. Ph.D.
Analyzed by: Approved by
Disclaimer: T.de laboraior/ is not responsible for data reported in structures/cc. which is dependent on volume collected by non-laboratory personnel. This lab is only responsible
for data reoortgd in structures/mmT This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim
oroouct endorsement by NVLAP or any other agency of the U.S. Government. This reports relates only to ;he samples reported above. Quality control data (ircluding 35%
confidence limits and laboraiory and analysis' accuracy and precision) is available upon request.
AccrsCited for NVLAP PLM/TEM #101187-0, NY State EA? #10879
Piii;e 2 i>/'2