Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
z HhuNtAULl AbbUCIAThS, ING. NYGUtH-WIG z
■< ■<
o 631-467-8477 5-BORO SAMPLING o
io METALS IN AIR co
[CALCULATION FOR OSHA ID121/125G- METALS IN AIR VIA CASSETTE FILTER (37MM MILLIPORE) & MOBILE VACUUM PUMPS u
I
o c
o jA= Concentration of Analyte in sample solution (|ig/ml) or (mg/L) CT
o
Ca3 o'
CD j B=Concentration of Blank in sample solution (gg/ml) or (mg/L) U
OO o
jSSV= Sample Solution Volume ASSV= Analyte concentration x Sample Solution Volume AR= (A X SSV) - (B X BSV) 3.
03
Ca5
■ BSV=Blank Sample Volume BBSV=Blank concentration x Blank Sample Volume AV O
!rAB= Reagent Blank Concentration (pg/ml) or (mg/L) o
o
c
! RABSV= Reagent Blank Sample Volume 3
CD
Jd= Dilution Factor (NONE)
Ino gravimetic factors ' ; ■ For the Trip Blank Analytical Value:
IAV= Air Volume Sampled AR= (B X BSV) - (RAB X RABSV)
I AR=Analytical Result AV
lARR=AnalytIcal Reportable Result in mg/m^ (rounded off to 3-sIgma)