Z PEDNEAULT ASSOCIATES, INC. NYCDEP - WTC
z
O 631-467-8477
1
jCALCULATION FOR OSHA1D121/125G- METALS IN AIR VIA CASSE^ FILTER (37MM MILLIPORE) & MOBILE VACUUM PUMPS
5-BORO SAMPLING
METALS IN AIR- o
co
o ■D
o
o
jA= Concentration of Analyte in sample solution (pg/ml) or (mg/L) I c
CT
Ca3
CD jB=Concentration of Blank in sample solution (pg/ml) or (mg/L) J R o'
O>
CD •SSV= Sample Solution Volume AS^= Analyte concentration x SatnpIc So lution Volume AR= (A X SSV) - (B X BSV) I ■0
O
cn 3.
■ BSV'.’BIank Sample Volume BBSV^BIank concentration x Blank Sa^j de Volume AV I 91
!rAB= Reagent Blank Concentration ((Xg/ml) pr (mg/L) D
I o
o
JrABSV= Reagent Blank Sample Volume I c
3
CD
! D= Dilution Factor (NONE) I
Ino gravimetic factoiis 1 For the Trip Blank Analytical Value:
AR= (B X BSV) - (RAB X RABSV) I
IAV= Air Volume Sampled 1
|AR=AnaIytical Result ; <1
£
AV I
•