PLM Bulk Asbestos Report
Applied Technology Services, Inc, Date Received 05/10/2002 SciLab Job No. 202052099
Attn: Steve Vanderwoude Date Examined 05/10/2002 P.O.# E02411
240 North Avenue ELAP Number 11480 Page 4 of 4
New Rochelle, NY 10801 RE; E02411
Client No./HGA Lab No. Asbestos Present Total % Asbestos
26-051002-19 202052099-13 No NAD
Location: 4th Floor /* Dust / E. Wall 12’ S Of Room F-405 Hall
Description: Grey, Heterogeneous, Dust
Asbestos Types:
Other Material: Cellulose 13.%, Fibrous glass 10.%, Synthetic fibers 2.%,
Non-fibrous 75. %
I
26-051002-20 202052099-14 No NAD
Location: 4th Floor / E. Wall In R. Room 400
Description: Grey, Heterogeneous, Dust
Asbestos Types:
Other Material: Cellulose 15.%, Fibrous glass 10.%, Synthetic fibers Trace,
Non-fibrous 75. %
Reportins Notes:
(1) Composite analysis results for Heterogenous debris samples may be highly vanable due to inhomogenities in matenals present
Analyzed by: Jonathan Teda ______
♦NAD/NSD = no asbestos detecljfd, NA = not analyzed, NAVPS = not analyzed / positive stop; PLM Bulk Asbestos Analysis
by EPA 600/M4-82-020 per 40 cW 763 (NVLAP Lab #200546-0) and ELAP PLM Analysis Protocol 198.1 for New York
samples (NYSDOH ELAP Lab # 11480), Note: PLM is not consistently reliable in detecting asbestos in floor covenngs and
similar non-fnable orgamcally bound matenals. TEM is currently the only method that can be used to determine if this matenal
can be considered or treated as non-asbestos-contaimng in New York State (also see EPA Advisory for floor tile, FR 59,146,
38970, 8/1/94). National Institute of Standards and Technology Accreditation requirements mandate that this report must not be