NYC 9/11 Public Portal Document
tMbL MANHrtlIAN HAbt B2
Bb/ib/zuai i«:ob
New York Lab
307 West 38th atrsef. New York, NY 10018 EMSL
Ptwna: 212-290.0051 Fix: 2123900066 Email;
Attn. Juan Salcedo Customer ID' EMT51
Emteoue Corporation Customer PO;
505 Eighth Avenue, Suite 900
New York, NY 10018 Received 09/14/01 a.50 PM
Fax; (212)631-8066 phone. 212-631-9000
EMSL Order. 030104243
Project: 01-0458 / Reckson Associates /100 Wall St. NY, NY
/12th Floor
EMSL Project ID.
Analysis Date: 9/14/2001
Asbestos Analysis of Bulk Materials by PLM via the NY State ELAP 198.1 Method
ISSilkAshsxtos Asbeetes
Sample Location Appearance Treatment % Fibrous % Non-FIbrous % Type
09A NW side of 12th Rose/White/Gray Teased 10.00% Synthetic 3.00% Non-fibrous (other) None Oetectad
0301042190010 Fl AC-4/AC- Fibrous Dissolved 85.00% Glass
FlHers Heterogeneous 2.00% Cellulose
10A NE side of 12th Ft Rose/White/Gray Teased 10.00% Synthetic 5 00% Non-fibrous (other) NoneOateeted
(00104219^10 ACS A-B / AC Fibrous Dissoivsd 85.00% Glass
H«tBroa«heou$ <1% Cellulose
11A NE »we of 12th Fl Rosewhite/Gray Teased 12,00% Synthetic 3.00% Non-fibrous (other) None Detected
taiM01243^1 AC3A-B/AC Ftotous Dissolved 8500% Glass
FNIer Heterogeneous <1% Cellulose
12A NE side of 12th Fl Rose/White/Grsy Teased 10.00% Synthetic 5 00% Non-fibrous (other) None Detected
0391<M24»»t2 AC3A-e/AC Fibrous Dissolved 63 0O% asss
Filter Heterogeneous 2.00% Cellulose
asm YaMfana
Analyet Laboreloiy Manager
or other approved signatory
WJM tw Been Knau Io min sifcuo* In « ««mII p«ro»ni»B» ot wryiM »«»ai oonwn N«g«ih(» UM nuOt cennoi ns gmn«4»«i». Stmoot npatai w<i % y tm
astscua SHAm ns Med viWl TEM. ths sbwa WM itoon rswtos w ms ntrrs Msd TWt rsnon msy noi be rtpreduesd. Smpi n lUII. WWUU ariusn spprovsi by EMSL
AnslM. Ilk Ths Sbnvs MSt km* rm bs uisa by Ihs aisrS w dsim prscuci ttldoreetnore by Nvuu* nor sny lesney «r ms Uniisd Stets* Gsvsnvnent,
nsliApsi<4n<t»l>veMSt.»M<ihe<lsn(WVtAP»101(l4e-a),WYBAP 11508____________ _ ___________ ________ ____
2
CITY_21MC100_002388430
NYC-WTC_000390518
OCR can misread numbers and units. Confirm readings against the page image before using them.