NYC-WTC_000420968
Permit-related correspondence regarding exterior facade cleaning and condo unit considerations.
4 shared non-person entities · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗GAC Environmental assessment of environmental impact to 85 [name] following 9/11 events; inspections noted.
NYC-WTC_000390367–000390369OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
85 John Street - Environmental Assessment November 28, 2001 Page 2 of 3
3. Dust samples were taken on September 17, 2001. Samples were taken from the exterior and interior of the building, as well as from the roof. All samples were analyzed by Polarized Light Microscopy (“PLM”). 4. Interviews were conducted with personnel from the building.
Laboratory Results
■ The results of the PID Meter indicate that no Volatile Organic Compounds ("VOC”) were found during the time that monitoring was performed.
■ The results indicate that all of the dust analyzed on September 17, 2001 contained less than one (1) percent asbestos. Samples, which contain less than one (1) percent asbestos, are considered by the NYC, NYS and EPA not to be an "asbestos containing material”.
■ Listed below are the areas where air monitoring was performed in the building:
1. Apt. #1 IB 2. Apt. #1 IE 3. 14"’Floor Corridor 4. 12"’Floor Corridor 5. lO"’Floor Corridor 6. 8"’Floor Corr idor 7. 6"’Floor Corridor 8. 4'" Floor Con-idor 9. Apt.#4F 10.2"" Floor Corridor
The asbestos air monitoring results indicated No Structures Detected ("NSD”) on 9 of 10 samples analyzed. The sample on the 4*'’ Floor - Apt. #4F registered at 14.3 structures/mm' The EPA action level for asbestos in air is 70 structures'mm“. The results indicate that all asbestos levels were found well below the EPA action level; during the time that air monitoring was performed.
CITY_21MC100_002885832
NYC-WTC_000390368
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000420968
Permit-related correspondence regarding exterior facade cleaning and condo unit considerations.
4 shared non-person entities · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000230980
Application submitted to the DEP regarding cleaning procedures for a residential condominium, including exterior facade and interior duct work.
4 shared non-person entities · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000282072
Environmental inspection report with air monitoring recommendations for Broadway site.
4 shared non-person entities · similarity 0.952
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000408671
Indoor air/dust tests after WTC collapse; metals, PCBs, dioxin analyses; one sample above standard.
4 shared non-person entities · 1 shared topics · similarity 0.945
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000108678
Document page summarizing positive and negative counts for asbestos analysis via PLM, PCM, and TEM methods.
11 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000106330
Letter reporting asbestos testing results for air and dust at Borough of Manhattan Community College in February 2002.
6 shared non-person entities · 1 shared topics · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000123868
Letter from the NYC Department of Health dated February 8, 2002, summarizing environmental sampling and asbestos testing results at a residential building.
3 shared non-person entities · similarity 0.948
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000151361
A letter defending the validity of DEP and contractor data used to clear residential units at 114 Liberty Street for re-occupancy.
4 shared non-person entities · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117493
Cover page for a report detailing annual assessment, bulk sampling, and air monitoring activities at the specified address.
6 shared non-person entities · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
5 shared non-person entities · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155002
Federal agencies respond to resident concerns regarding the validity of environmental clearance data for 114 Liberty Street.
4 shared non-person entities · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154948
Federal agencies respond to resident concerns regarding the validity of environmental clearance data for 114 Liberty Street.
4 shared non-person entities · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000108678
Document page summarizing positive and negative counts for asbestos analysis via PLM, PCM, and TEM methods.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321783
Chain-of-custody for asbestos in air, dust, and fibers in WTC area.
Similarity score 0.967 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000408404
Chain-of-custody style results for ambient and [name] evaluations; sample locations and CFU data.
Similarity score 0.966 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390030
Environmental evaluations comparing dust/air levels to indoor asbestos standards post-9/11.
Similarity score 0.966 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320589
Dust and air sampling protocol with TEM/PLM criteria and action thresholds.
Similarity score 0.966 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176137
Summary report detailing air and settled dust sampling results from a residential building, including methods for fiber analysis.
Similarity score 0.966 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000108678
Document page summarizing positive and negative counts for asbestos analysis via PLM, PCM, and TEM methods.
Similar indexed content
NYC-WTC_000420968
Permit-related correspondence regarding exterior facade cleaning and condo unit considerations.
Similar indexed content
Application submitted to the DEP regarding cleaning procedures for a residential condominium, including exterior facade and interior duct work.
Similar indexed content
NYC-WTC_000282072
Environmental inspection report with air monitoring recommendations for Broadway site.
Similar indexed content
NYC-WTC_000106330
Letter reporting asbestos testing results for air and dust at Borough of Manhattan Community College in February 2002.
Similar indexed content