NYC-WTC_000390334
Chain-of-custody documentation for PCM air sampling at 80 [name], New York, Dec 13, 2001.
6 shared non-person entities · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗Chain-of-custody and PCM air sampling results for 80 [name], New York, Oct 2001.
NYC-WTC_000390341–000390342OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
WSA Management JLC Project #01-2171 October 29, 2001 page 2 Air alina Analysis and Procedure
Introduction Air sampling is defined as the process of measuring the filter content of a known volume of air entrained on a filter membrane over a specified period of time. Each sample is cross-referenced by field designation and a JLC lab internal code to ensure proper, consistent handling through a chain of custody. Sample preparation takes place within an HEPA filter clean bench to avoid any possible contamination.
Methodology Test procedures for these samples conform to the National Institute of Occupational Safety and Health (NIOSH) standards.
Air sampling was conducted at a level approximating the breathing zone of persons anticipated to be present in the area during normal operations. Samples collected should represent the area's typical airborne fiber concentration.
All samples were collected on fully exposed 25 millimeter, 0.8 micrometer (pm) cellulose ester membrane air sampling cassettes with conductive cowl.
Analytical Procedures A section of the filter approximating twenty-five percent of the total filter was removed and placed on a pre-cleaned microscope slide and then exposed to approximately 250 microliter (pl) of acetone vapor. A single 3.0 - 3.5 pl drop of triacetin was applied and a clean #1.5 cover slip was placed upon the filter. The prepared slide was then heated on a slide heater until clarity allowed analysis to be conducted.
Analysis was accomplished utilizing a Phase Contrast Microscope in accordance with NIOSH 7400 method, counting rule "A."
Phase Contrast Microscopy JLC Environmental's laboratory uses an Olympus BH-PC Phase Contrast Microscope, (PCM) equipped with a Walton-Beckett Graticule. Samples were analyzed by first dissolving the filter through a chemical process (described above) and then counting the fibers with PCM at 400x magnification. Phase contrast increases the light contrast between the object and the background, thus enhancing the microscopist's ability to see fibers. Normally, 100 microscopic fields or 100 fibers are counted, whichever occurs first.
Analytical Results The "Summary of Analytical Results" represents the results of the analysis of the samples. The PCM limit of reliable quantification is less than 0.01 fibers/cubic centimeter (f/cc) of air. If final tests do not meet these requirements, the entire work site must be re-cleaned and re-tested.
CITY_21MC100_002885796
NYC-WTC_000390342
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000390334
Chain-of-custody documentation for PCM air sampling at 80 [name], New York, Dec 13, 2001.
6 shared non-person entities · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390298
Chain of custody for PCM air sampling analysis for 80 [name], NY.
5 shared non-person entities · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390349
Chain-of-custody and results for PCM air sampling at 80 [name], NY, conducted for WSA Management.
5 shared non-person entities · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390305
Chain of custody for PCM air sampling at 80 [name], NY; signatures and routing.
5 shared non-person entities · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390358
Chain-of-custody and results for PCM air samples at 80 [name], NY.
5 shared non-person entities · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390318
PCM air sampling analysis report for 80 [name], New York, Dec 13–14, 2001.
5 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000220388
Letter enclosing analytical results for PCM air sampling conducted at 80 West Street on December 3, 2001.
4 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390329
Chain-of-custody and PCM air sampling results for 80 [name], New York, Dec 3, 2001.
5 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367185
Chain-of-custody for PCM air sampling at 2 [name] Ave, NYC, Sept–Oct 2001.
2 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000306169
Reference for PCM air sampling analysis conducted at 55 Broadway.
3 shared non-person entities · 1 shared topics · similarity 0.958
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321929
Log of PCM air sampling analysis and courier details from JLC Environmental.
3 shared non-person entities · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000277295
Chain-of-custody and results for PCM air sampling at 100 [name], with analysis plan and contact.
3 shared non-person entities · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000390334
Chain-of-custody documentation for PCM air sampling at 80 [name], New York, Dec 13, 2001.
Similar indexed content
NYC-WTC_000390298
Chain of custody for PCM air sampling analysis for 80 [name], NY.
Similar indexed content
Chain-of-custody and results for PCM air sampling at 80 [name], NY, conducted for WSA Management.
Similar indexed content
NYC-WTC_000390305
Chain of custody for PCM air sampling at 80 [name], NY; signatures and routing.
Similar indexed content
Chain-of-custody and results for PCM air samples at 80 [name], NY.
Similar indexed content