NYC-WTC_000390036
Dust/air evaluation report comparing impacted vs non-impacted areas; indoor standards reference.
7 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗Environmental evaluations comparing dust/air levels to indoor asbestos standards post-9/11.
NYC-WTC_000390030–000390035OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
3 Common Not Sampled Not Sampled <.001 NA 3 Res 1 Not Sampled Not Sampled <.001 NA 3 Res 2 Not Sampled Not Sampled <.001 NA 3 Res 2 X Not Sampled Not Sampled <.001 NA
Building 4 PLM [%] TEM [%] PCM [f/cc] TEM [f/cc] 4 Outside Not Sampled Not Sampled 0.001 NA 4 Common ND <1 0.001 NA 4 Res 1 ND <1 <.001 NA 4 Res 2 ND <1 0.001 NA 4 Outside X Not Sampled Not Sampled <.001 NA 4 Common X Not Sampled Not Sampled 0.001 NA
Building 5 PLM [%] TEM [%] PCM [f/cc] TEM [f/cc] 5 Outside 3.4 NA 0.002 NA 5 Common Not Sampled Not Sampled 0.002 NA 5 Res 1 <1 0.002 NA 5 Res 2 ND <1 <.001 NA 5 Outside X Not Sampled Not Sampled 0.003 NA Building 5 Noles: Upon reinspection DEP found no visible dust in the outdoor area at this location.
Building 6 PLM [%] TEM [%] PCM [f/cc] TEM [f/cc] 6 Outside Not Sampled Not Sampled <.001 NA 6 Common ND <1 <.001 NA 6 Res 1 ND ND <.001 NA 6 Res 2 ND ND <.001 NA 6 Res 2 X Not Sampled Not Sampled 0.002 NA
Building 7 PLM [%] TEM [%] PCM [f/cc] TEM [f/cc] 7 Outside ND 1.7 <.001 NA 7 Common ND ND 0.001 NA 7 Res 1 ND ND 0.001 NA 7 Res 2 ND ND <.001 NA 7 Window Sill ND ND NA NA Building 7 Notes: DEP reinspected, collected samples, and found no asbestos-containing material.
Building 8 PLM [%] TEM [%] PCM [f/cc] TEM [f/cc] 8 Outside Not Sampled Not Sampled 0.001 NA 8 Common ND ND 0.002 NA 8 Res 1 ND ND 0.003 NA 8 Res 2 ND ND 0.002 NA
Building 9 PLM [%] TEM [%] PCM [f/cc] TEM [f/cc] 9 Outside Not Sampled Not Sampled <.001 NA 9 Common ND ND 0.001 NA 9 Res 1 ND <1 0.001 NA 9 Res 2 ND <1 0.003 NA 9 Common X Not Sampled Not Sampled 0.001 NA
Building 10 PLM [%] TEM [%] PCM [f/cc] TEM [f/cc] 10 Outside ND ND 0.001 NA 10 Common ND 1.5 0.002 NA 10 Res 1 ND ND 0.001 NA 10 Res 2 ND ND 0.001 NA
CITY_21MC100_002917556
NYC-WTC_000390031
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000390036
Dust/air evaluation report comparing impacted vs non-impacted areas; indoor standards reference.
7 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000408404
Chain-of-custody style results for ambient and [name] evaluations; sample locations and CFU data.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307871
Draft report on ambient and indoor dust/air evaluations with TEM/PLM procedures for WTC cause.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302824
Draft report comparing dust/air asbestos levels to indoor standards for WTC area.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362177
Ambient and indoor asbestos evaluation for WTC area, Nov 2001–Dec 2001.
6 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321783
Chain-of-custody for asbestos in air, dust, and fibers in WTC area.
7 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320579
Draft outline for ambientdust/air evaluations at WTC, including sampling plan.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320589
Dust and air sampling protocol with TEM/PLM criteria and action thresholds.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242808
Ambient dust evaluation with TEM/PLM decision rules for asbestos-containing material.
7 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242829
Tabled results for asbestos in air and dust; building-level data for residential sites.
4 shared non-person entities · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242814
Asbestos in dust and air results across residential buildings; PLC/TEM decision points.
3 shared non-person entities · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000242822
Dust and air asbestos assessments with action thresholds and TEM confirmation guidance.
5 shared non-person entities · similarity 0.958
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000390036
Dust/air evaluation report comparing impacted vs non-impacted areas; indoor standards reference.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321783
Chain-of-custody for asbestos in air, dust, and fibers in WTC area.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139656
Forwarded spreadsheet compiling residential asbestos sampling results collected in November-December 2001, including Building 11 reoccupancy assessment.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000408404
Chain-of-custody style results for ambient and [name] evaluations; sample locations and CFU data.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164732
Draft spreadsheet of asbestos sampling results from residential locations collected November-December 2001, circulated for review.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320579
Draft outline for ambientdust/air evaluations at WTC, including sampling plan.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000390036
Dust/air evaluation report comparing impacted vs non-impacted areas; indoor standards reference.
Similar indexed content
NYC-WTC_000408404
Chain-of-custody style results for ambient and [name] evaluations; sample locations and CFU data.
Similar indexed content
NYC-WTC_000321783
Chain-of-custody for asbestos in air, dust, and fibers in WTC area.
Similar indexed content
NYC-WTC_000320579
Draft outline for ambientdust/air evaluations at WTC, including sampling plan.
Similar indexed content
NYC-WTC_000307871
Draft report on ambient and indoor dust/air evaluations with TEM/PLM procedures for WTC cause.
Similar indexed content